Affiliations: Visualization Research Center, Niigata University,
8050 Ikarashi-2, Niigata, 950-2181, Japan. E-mail:
fujisawa@eng.niigata-u.ac.jp
Abstract: In this paper, temperature measurement of axisymmetric dilute
hydrogen flame is described using digital laser-speckle technique, which allows
the measurement of refractive index field of the flame without any tracers. The
measurement system consists of laser and CCD camera, which are placed in-line
configuration. The temperature field of the flame is derived from the
refractive index field using the cross-correlation analysis of the speckle
pattern with and without flame. The influence of the species concentration on
the temperature measurement is evaluated from the gas composition in the flame
using gas chromatography. It is found that the temperature field measured by
the present method with concentration correction agrees with that of the
thermocouple measurement within an experimental accuracy, suggesting the
usefulness of this measurement technique.