Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: O'Neil, Margaret E. | Fragala-Pinkham, Maria A. | Forman, Jeffrey L. | Trost, Stewart G.
Affiliations: Department of Physical Therapy and Rehabilitation Sciences, College of Nursing and Health Professions, Drexel University, Philadelphia, PA, USA | Franciscan Hospital for Children, Research Center for Children with Special Health Care Needs, Brighton, MA, USA | Department of Pediatric Rehabilitation Medicine, Franciscan Hospital for Children, Brighton, MA, USA | Queensland Institute of Technology, Institute of Health and Biomedical Innovation, St Lucia, QLD, Australia
Note: [] Corresponding author: Margaret E. O'Neil, Drexel University, Mail Stop 7502, 1601 Cherry Street, Phila, PA 19102, USA. Tel.: +1 267 359 5546; Fax: +1 267 359 5576; E-mail: moneil@drexel.edu
Abstract: PURPOSE: The purposes of this study were to: 1) establish inter-instrument reliability between left and right hip accelerometer placement; 2) examine procedural reliability of a walking protocol used to measure physical activity (PA); and 3) confirm concurrent validity of accelerometers in measuring PA intensity as compared to the gold standard of oxygen consumption measured by indirect calorimetry. METHODS: Eight children (mean age: 11.9; SD: 3.2, 75% male) with CP (GMFCS levels I–III) wore ActiGraph GT3X accelerometers on each hip and the Cosmed K4b^{2} portable indirect calorimeter during two measurement sessions in which they performed the six minute walk test (6MWT) at three self-selected speeds (comfortable/slow, brisk, fast). Oxygen consumption (VO2) and accelerometer step and activity count data were recorded. RESULTS: Inter-instrument reliability of ActiGraph GT3X accelerometers placed on left and right hips was excellent (ICC=0.96–0.99, CI_{95}: 0.81–0.99). Reproducibility of the protocol was good/excellent (ICC=0.75–0.95, CI_{95}: 0.75–0.98). Concurrent validity of accelerometer count data and VO2 was fair/good (rho=0.67, p< 0.001). The correlation between step count and VO2 was not significant (rho=0.29, p=0.2). CONCLUSION: This preliminary research suggests that ActiGraph GT3X accelerometers are reliable and valid devices to monitor PA during walking in children with CP and may be appropriate in rehabilitation research and clinical practice. ActiGraph GTX3 step counts were not valid for this sample and further research is warranted.
Keywords: Physical activity measurement, accelerometry, cerebral palsy
DOI: 10.3233/PRM-140292
Journal: Journal of Pediatric Rehabilitation Medicine, vol. 7, no. 3, pp. 233-240, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl