Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Millet, P. | Girardin, E. | Braham, C. | Lodini, A.;
Affiliations: LACM, EA3304, Université de Reims, Reims, France | LM3, ENSAM, Paris, France | C.E.A, C.E.N., Saclay, Laboratoire Léon Brillouin, Gif sur Yvette, France
Note: [] Corresponding author.
Abstract: During clinical use of an implant, the mechanical stresses are added to pre-existing residual stresses. The magnitude of these stresses affects the hydroxyapatite coating’s performance. We intended to study in this work, by neutron diffraction and conventional X-ray diffraction methods, the macrostresses induced by a plasma-spraying process in the coating and at the interface. Neutron diffraction is a suitable technique to study the strain distribution in a bulk material. X-ray diffraction has been used to determine residual stress in the hydroxyapatite coating. Using neutron diffraction method, we calculate the stress on the titanium alloy but see no real difference between the stress on the coated and the non-coated samples. With X-ray diffraction method, it appears that the stress level is compressive on every sample. The major interest of neutron diffraction method is that measurements can be done on a thick coating, in a non-destructive way with the disadvantage of a large gauge volume that we had to use. Polishing is necessary for measurements inside the material when using X-ray method. This destructive method may alter the stress field of the deposit.
Keywords: Implant, Hydoxyapatite coatings, Stress, Strain, Neutron diffraction, X-ray diffraction
DOI: 10.1080/10238160108200176
Journal: Journal of Neutron Research, vol. 9, no. 2-4, pp. 443-448, 2001
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl