Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Abujarir, R. | Salama, H. | Greer, W. | Al Thani, M. | Visda, F.
Affiliations: Division of Neonatology, Women's Hospital, Hamad Medical Corporation, Doha, Qatar | Department of Clinical Planning, Sidra Medical and Research Center, Doha, Qatar
Note: [] Corresponding author: Dr. Husam Salama, Department of Pediatrics, Women's Hospital, Hamad Medical Corporation, PO Box 3050, Doha, Qatar. Tel.: +974 4393249; Fax: +974 4396142; E-mail: Hsalama1@hmc.org.qa
Abstract: Introduction: Elevated sound levels in neonatal intensive care units may cause undesirable effects and influence the stability of vital signs in moderately sick newborn infants. Objective: To evaluate the effect of using earmuffs on the seven most common vital signs in newborns in NICUs. Methods: This is a prospective controlled study. All term and pre-term infants admitted to the NICU were randomized to either an “earmuffs” or a “no earmuffs” area and underwent hourly measurements and recording of vital signs during routine NICU activity for three consecutive days. Data were collected by sampling data from the routine continuous monitoring of heart rate (HR), respiratory rate (RR), oxygen saturation (OSAT), blood pressure (BP), FIO2 requirement, pain score (PS), and temperature (T). Exclusion criteria included neonates on high frequency ventilation, sedation and congenital anomalies with possible auditory system involvement. Results: The study included 182 infants; of them 100 infants completed the 72-hour measurements. Vital signs of fifty newborn infants in each group were recorded for a period of 72 hours. During this time, the observed linear increase in heart rate was significantly reduced within the earmuffs group (139 versus 146 beat per minute) with p value <0.001, which also exhibited a similar significant decrease in systolic BP, although there was no evidence of significant difference between-group effect for diastolic BP and mean blood pressure. The average RR in the EM group was significantly lower than the NEM group for the entire 72-hour period (0.001), while temperature showed no significant difference between the two groups across the same time-period. Earmuffs also conferred a small but significant improvement in the gradual increase of the average O2 saturation (p value = 0.01). Similar improvement due to earmuffs could also be seen in the infants' requirement for oxygen (days); the average oxygen requirement was 1.8 days versus 2.5 days with p value of <0.001. Conclusion: Wearing earmuffs inside the NICU had a positive effect on the infants' vital signs.
Keywords: Noise, NICU, infant, newborn, earmuff
DOI: 10.3233/NPM-2012-57511
Journal: Journal of Neonatal-Perinatal Medicine, vol. 5, no. 3, pp. 249-259, 2012
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl