Authors: Hentschel, R. | Mohr, T. | Pelz, K. | Zahradnik, H.P. | Beck, K.H.;
Affiliations: Division of Neonatology and Intensive Care, Center for Pediatrics and Adolescent Medicine, University of Freiburg, Freiburg, Germany | Department of Transfusion Medicine and Hemostaseology, University of Freiburg, Freiburg, Germany | Department of Microbiology, University of Freiburg, Freiburg, Germany | Department of Obstetrics and Gynecology, University of Freiburg, Freiburg, Germany | MDK – Medical Service of Statutory Health Insurance Companies, Lahr, Germany
Note: [] Corresponding author: Roland Hentschel, Center for Pediatrics and Adolescent Medicine, Division Neonatology and Intensive Care, Mathildenstr, 1, 79106 Freiburg, Germany. Tel.: +49 761 270 4319; Fax: +49 761 270 4399; E-mail: roland.hentschel@uniklinik-freiburg.de
Abstract: Objective: Even though red blood cells from cord blood (CB) have been investigated for many years for the purpose of autologous retransfusion to newborns this technique is still far from clinical routine. In severely ill neonates fresh frozen plasma from donors is frequently transfused for volume expansion or as a source of coagulation factors but autologous plasma transfusion has not been described. Methods: We investigated 35 CB preparations of preterm and term newborns for sterility and fast provision of either red blood cell concentrate (RBC) or plasma with respect to quality of both components and time needed for bacterial testing. CBs and 34 control RBCs from regular blood donors were collected in citrate-phosphate-dextrose solution (CPD). RBCs and plasma were prepared in sodium-adenine-glucose-mannitol (SAGM). Swabs were taken from the placenta for cultivation of bacteria. Quality of stored blood was assessed in RBCs on day 0, 3, 8, 14 and 42, respectively, and tests for activated coagulation were done in thawed plasma. Results: CB harvesting started within 30 minutes after umbilical cord clamping. A mean CB volume of 50.6 mL (range 19.6 mL to 90.6 mL) was collected. None of the bacteria detected in the placenta smear could be detected in the collected CBs. Mean Hct in the RBC was 53 ± 7%. Glucose, pH, ATP and 2,3-DPG decreased over time, while lactate, potassium, hematocrit and hemolysis increased. Sterility of CBs was verified within 72 hours. Prothrombin fragment 1 + 2 (F1 + 2; n = 34) was elevated (3.9 ± 2.5 nmol/L), and high levels of thrombin-antithrombin complexes (TAT) were detected also in the majority of newborns' plasma (>61 μg/L; n = 31). Discussion: Suitability of RBCs from CB must be restricted to 14 days, mainly because of a decreasing pH. Probably, by adding CPD solution at an amount appropriate for the actual volume of CB it will be possible to extend the storage time. However, retransfusion of plasma harvested from CB seems imposssible, due to the activated coagulation process.
Keywords: Cord blood, infant, newborn, erythrocyte, plasma, autologous retransfusion
DOI: 10.3233/NPM-2011-2720
Journal: Journal of Neonatal-Perinatal Medicine, vol. 4, no. 1, pp. 1-8, 2011
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl