Article type: Research Article
Authors: Jordan, Brian K.a; * | Bernard, Leahb | Segel, Sallyc | Go, Mitzi D.a | Schilling, Dianea | McEvoy, Cindy T.a
Affiliations: [a] Doernbecher Children’s Hospital, Oregon Health & Science University, Portland, Oregon, USA | [b] Asante Physician Partners, Medford, Oregon, USA | [c] Peace Health Southwest Medical Center, Vancouver, Washington, USA
Correspondence: [*] Address for correspondence: Brian K. Jordan, Division of Neonatology, Department of Pediatrics, Oregon Health & Science University, 2222 CDRC-P, 707 SW Gaines St, Portland, OR, 97239, USA. Tel.: +1 503 494 1077; E-mail: jordabr@ohsu.edu.
Abstract: BACKGROUND:Premature infants are born with immature lungs that demonstrate abnormal pulmonary function with differences in passive respiratory system compliance and resistance, and functional residual capacity. To our knowledge, no studies have evaluated differences in neonatal pulmonary function based on the type of twin gestation, or chorionicity. Given the effect of chorionicity on outcomes, we aimed to study the effect of twin type, monochorionic monoamniotic (MCMA) vs dichorionic diamniotic (DCDA), on neonatal early pulmonary function tests. METHODS:In this prospective cohort study, 5 sets of DCDA twins were matched to 5 sets of MCMA twins on gestational age at delivery, latency from antenatal corticosteroid exposure, birthweight, race and gender. Mean values were compared for passive respiratory system compliance and resistance, functional residual capacity, and tidal volume. RESULTS:MCMA infants had a significantly lower compliance (0.64 vs 1.25 mL/cm H2O /kg; p = 0.0001) and significantly higher resistance (0.130 vs 0.087 cm H2O /mL/sec; p = 0.0003) than DCDA infants. Functional residual capacity was lower for MCMA than DCDA infants (17.5 vs 23.4 mL/kg; p = 0.17). Further, 80% of MCMA infants required intubation for surfactant administration compared to 20% of DCDA infants, indicating the clinical significance of these objective measures. CONCLUSIONS:Due to the matched case-control design, causality cannot be established. However, we speculate that these differences in lung function may derive from differential exposure to preterm labor and endogenous maternal corticosteroid exposure. Further study is necessary to establish the true causal relationship.
Keywords: Chorionicity, function residual capacity, neonate, pulmonary function, respiratory system compliance, respiratory system resistance, twins
DOI: 10.3233/NPM-221113
Journal: Journal of Neonatal-Perinatal Medicine, vol. 16, no. 1, pp. 87-92, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl