Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Fiatt, M.a | Bosio, A.C.a | Neves, D.a | Symanski da Cunha, R.a | Fonseca, L.T.a | Celeste, R.K.b; *
Affiliations: [a] Hospital Criança Conceição, Neonatal Intensive Care Unit, Porto Alegre, Brazil | [b] Departamento de Odontologia Preventiva e Social, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil
Correspondence: [*] Address for correspondence: Roger Keller Celeste, Department of Preventive and Social Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos 2492, 3° andar, Porto Alegre –RS - CEP 90035 003, Brazil. Tel.: +55 51 3308 5356; E-mail: roger.keller@ufrgs.br.
Abstract: BACKGROUND:Prevalence of extubation failure in neonates may be up to 80%, but evidence to determine if a neonate is ready for extubation remains unclear. We aim to evaluate a spontaneous breathing trial accuracy with minimum pressure support to predict success in neonates’ extubation and identify variables related to failures. METHODS:This is a diagnostic accuracy study based on a cohort study in an intensive care unit with all eligible newborn infants subjected to invasive mechanical ventilation for at least 24 hours submitted to the trial for 10 minutes before extubations. The outcome was failures of extubations, considered if reintubation was needed until 72 hours. RESULTS:The incidence of failure was 14.7%among 170 extubations. There were 145 successful extubations; of these, 140 also passed the trial with a sensitivity of 96.5%(95%CI: 92.1–98.9). Of the 25 extubations that eventually failed, 16 failed the test with a specificity of 64.0%(95%CI: 42.5–82.0). The negative predictive value was 76.2%, and the positive predictive value was 94%. In stratifying by weight, the accuracy was >98.7%for neonates weighting >2500 g, but 72.5%for those weighing <1250 g. Extubation failures occurred more frequently in smaller (p = 0.01), preterm infants (p = 0.17), with longer ventilation time (p = 0.05), and having a hemodynamically significant persistent arterial duct (p = 0.01), compared with infants whose extubation was successful. CONCLUSION:The spontaneous breathing trial with minimum pressure support ventilation seems to predict extubation success with great accuracy in full-term and larger neonates.
Keywords: Artificial breathing, airway extubation, neonatal intensive care, validation study
DOI: 10.3233/NPM-200573
Journal: Journal of Neonatal-Perinatal Medicine, vol. 14, no. 3, pp. 375-382, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl