Article type: Research Article
Authors: Said, M.M.a | Rivera, O.c | Mikesell, G.T.b | Rais-Bahrami, K.a; *
Affiliations: [a] Departments of Neonatology, Children’s National Medical Center and The George Washington University School of Medicine, Washington, DC, USA | [b] Cardiovascular Surgery, Children’s National Medical Center and The George Washington University School of Medicine, Washington, DC, USA | [c] Biomedical Engineering, Children’s National Medical Center and The George Washington University School of Medicine, Washington, DC, USA
Correspondence: [*] Address for correspondence: K. Rais-Bahrami, MD, Department of Neonatology Children’s National Medical Center, 111 Michigan Avenue, NW Washington, DC 20010, USA. Tel.: +1 202 476 4764; Fax: +1 202 884 3459; E-mail: kraisbah@childrensnational.org.
Abstract: BACKGROUND: Recirculation of oxygenated blood in venovenous extracorporeal membrane oxygenation (VV ECMO) can decrease the oxygen delivery provided by the ECMO support. This study investigated the influence of central hemodynamics and catheter position on the amount of recirculation and oxygen delivery during VV ECMO. METHODS: Recirculation was measured in seven newborn lambs (mean weight 4.7 kg) during VV ECMO using the ELSA Monitor (Transonic Systems, Inc., Ithaca, NY) and using the central venous line (CVL) method. The ECMO pump was set at the prescribed flow of 110–120 mL/kg/min for a targeted oxygen delivery rate of 6cc/kg/min without recirculation. Hemodynamic status before and during ECMO was also measured by the COstatus Monitor (Transonic Systems, Inc.,Ithaca, NY). RESULTS: Lambs with a higher cardiac index (>160 ml/min/kg), had a tendency to have higher percent oxygen delivery (65–94%, at prescribed flow) while lambs with lower cardiac index (<150 ml/min/kg), tended to have lower percent oxygen delivery (39–62%, at prescribed flow). ELSA recirculation measurements had a squared correlation coefficient R2 = 0.8 with the CVL method. CONCLUSIONS: The ELSA monitor provides an easy to use, non-invasive method to measure recirculation in VV ECMO. The data suggests that cardiac function may play an important prognostic role in achieving effective VV ECMO support.
Keywords: Extracorporeal membrane oxygenation, neonate, animal model, oxygen, cardiac
DOI: 10.3233/NPM-171692
Journal: Journal of Neonatal-Perinatal Medicine, vol. 10, no. 2, pp. 139-145, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl