Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Sreeja, S; * | Muhammad Noorul Mubarak, D.
Affiliations: Department of Computer Science, University of Kerala, Karyavattom Campus, Trivandrum, Kerala, India
Correspondence: [*] Corresponding author: Sreeja S. E-mail: sreebhav@gmail.com.
Abstract: MRI-Only Radiation (RT) now avoids some of the issues associated with employing Computed Tomography(CT) in RT chains, such as MRI registration to a separate CT, excess dosage administration, and the cost of recurrent imaging. The fact that MRI signal intensities are unrelated to the biological tissue’s attenuation coefficient poses a problem. This raises workloads, creates uncertainty as a result of the required inter-modality image registrations, and exposes patients to needless radiation. While using only MRI would be preferable, a method for estimating a pseudo-CT (pCT)or synthetic-CT(sCT) for producing electron density maps and patient positioning reference images is required. As Deep Learning(DL) is revolutionized in so many fields these days, an effective and accurate model is required for generating pCT from MRI. So, this paper depicts an efficient DL model in which the following are the stages: a) Data Acquisition where CT and MRI images are collected b) preprocessing these to avoid the anomalies and noises using techniques like outlier elimination, data smoothening and data normalizing c) feature extraction and selection using Principal Component Analysis (PCA) & regression method d) generating pCT from MRI using Deep Convolutional Neural Network and UNET (DCNN-UNET). We here compare both feature extraction (PCA) and classification model (DCNN-UNET) with other methods such as Discrete Wavelet Tranform(DWT), Independent Component Analysis(ICA), Fourier Transform and VGG16, ResNet, AlexNet, DenseNet, CNN (Convolutional Neural Network)respectively. The performance measures used to evaluate these models are Dice Coefficient(DC), Structured Similarity Index Measure(SSIM), Mean Absolute Error(MAE), Mean Squared Error(MSE), Accuracy, Computation Time in which our proposed system outperforms better with 0.94±0.02 over other state-of-art models.
Keywords: Computed tomography, deep convolutional neural network, magnetic resonance imaging, principal component analysis, pseudocomputed tomography
DOI: 10.3233/JIFS-213367
Journal: Journal of Intelligent & Fuzzy Systems, vol. 43, no. 3, pp. 3021-3037, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl