Issue title: Fuzzy Systems for Medical Image Analysis
Guest editors: Weiping Zhang
Article type: Research Article
Authors: Liu, Xiaopei; * | Teng, Jianfu
Affiliations: School of Microelectronics, Tianjin University, China
Correspondence: [*] Corresponding author. X. Liu, School of Microelectronics, Tianjin University, China. E-mail: liuxiaopei@tjcu.edu.cn.
Abstract: In China, moyamoya disease is one of the main causes of stroke events in children and adults. Early diagnosis and early treatment can prevent irreversible damage to nerve function and greatly improve the quality of life of patients. Based on the improved sparse Bayesian low-dose CT image blind restoration algorithm, moyamoya disease diagnosis and treatment has important application value guidance and evaluation Cheng, through the retrospective analysis of the clinical characteristics, imaging characteristics and treatment of 105 patients with moyamoya disease diagnosed by Blind image restoration algorithm based on improved sparse Bayesian low dose CT from April 2012 to November 2015 in a hospital in Hefei City, we think that CT angiography has important application value in the diagnosis and treatment of moyamoya disease, and we can draw a conclusion. Among these 105 patients, women are the majority. The ratio of male to female was 1:1.188, and the peak period was 30– 40 years old. There were 41 cases of ischemic stroke and 64 cases of hemorrhagic stroke. 29 patients underwent STA-MCA bypass, temporal muscle compression and dural reversal. Blind image restoration algorithm based on improved sparse Bayesian low dose CT was reexamined. The results of Blind image restoration algorithm based on improved sparse Bayesian low dose CT and DSA were the same. It can be seen that Blind image restoration algorithm based on improved sparse Bayesian low dose CT is a reliable method to diagnose moyamoya disease, which can be used as a preoperative guidance and postoperative evaluation of bypass vessel patency and collateral circulation formation.
Keywords: CT angiography, moyamoya disease, artery bypass
DOI: 10.3233/JIFS-179610
Journal: Journal of Intelligent & Fuzzy Systems, vol. 38, no. 4, pp. 3867-3875, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl