Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Special Section: Intelligent tools and techniques for signals, machines and automation
Guest editors: Smriti Srivastava, Hasmat Malik and Rajneesh Sharma
Article type: Research Article
Authors: Narayan, Yogendra; * | Mathew, Lini | Chatterji, S.
Affiliations: Department of Electrical Engineering, National Institute of Technical Teachers Training and Research, Panjab University, Chandigarh, India
Correspondence: [*] Corresponding author. Yogendra Narayan, Electrical Engineering Department, National Institute of Technical Teachers Training and Research, Panjab University, Chandigarh 160019, India. E-mail: narayan.yogendra1986@gmail.com.
Abstract: Selection of suitable features plays a pivotal role in Electromyography pattern recognition (EMG-PR) based system designing. Time-domain features are widely used in EMG-PR based application and show improved proficiency in the development of rehabilitation robotics. Even though, the performance of existing features is not satisfactory. In this study, we proposed four novel time-domain features obtained by using first-order differentiation of original surface electromyogram (sEMG) signals feature. Here, sEMG signals were acquired from ten healthy volunteers with the help of myotrace400 device for six different arm movements. The data acquisition and pre-processing stage were carried out followed by the feature extraction process for better classification results. Four different classifiers namely, k-nearest neighbors (KNN), Linear discriminant analysis (LDA), Quadratic discriminant analysis (QDA) and Medium tree (MT) classifiers were utilized for the performance evaluation of proposed and conventional features. Experimental results demonstrate that proposed features extracted by using first-order differentiation of sEMG signals feature attained better classification accuracy with MT classifier as compared to the feature extracted from original sEMG signals with the conventional features. The accuracy of proposed feature based on first-order differentiation improved up to 6%. The results indicate that proposed features may be considered for developing the EMG-PR based system designing.
Keywords: sEMG signal, pattern recognition, time domain features, differentiation technique, classification accuracy
DOI: 10.3233/JIFS-169794
Journal: Journal of Intelligent & Fuzzy Systems, vol. 35, no. 5, pp. 5099-5109, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl