Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Special Section: Iteration, Dynamics and Nonlinearity
Guest editors: Manuel Fernández-Martínez and Juan L.G. Guirao
Article type: Research Article
Authors: Zhu, Xiaoganga; * | Choulli, E.b
Affiliations: [a] School of Software, Nanchang University, Nanchang, China | [b] Department of Mathematical and Statistics Science, University of Alberta, Edmonton, AB, Canada
Correspondence: [*] Corresponding author. Xiaogang Zhu, School of Software, Nanchang University, Nanchang 330047, China. E-mail: ccl201707@163.com.
Abstract: Traditional MESH-based high-voltage transmission line condition data acquisition and communication systems collect all types of transmission line related condition data using the wireless monitoring device, and transmit condition data to the information center point through the wireless mesh node by wireless multi-hopping. The traditional methods are easy to generate lagging response and the high energy consumption, which result in high system condition data loss rate and low comprehensive utilization value. Therefore, smart distribution network transmission line condition data acquisition and communication system is designed based on the overall structure of the system, including data acquisition module, data communication module, transmission line condition monitoring communication module, and wireless transmission module of transmission line condition data. Tension, ambient temperature, solar radiation temperature, and wind direction signals collected by the data acquisition module are transmitted to the data communication module. After the collected signals are packaged to wake up G24, and establish a good GPRS network connection for data transmission. The transmission line condition monitoring communication module adopts an embedded operating system, which can combine its own functions to cut down the operating system, to speed up the response to the interruption event. The MCU in the transmission line condition data acquisition and communication system of smart distribution network realizes the command control of G24 by sending AT commands through the UART port. Data exchange between terminal and master station and addition of data items ensure the normal and smooth data communication. The experimental results show that the designed system can significantly reduce the loss rate of transmission line condition data and improve the system’s comprehensive utilization capability.
Keywords: Smart distribution network, transmission line, condition data, communication system, interruption event, AT commands
DOI: 10.3233/JIFS-169732
Journal: Journal of Intelligent & Fuzzy Systems, vol. 35, no. 4, pp. 4107-4120, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl