Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Special Section: Ambient advancements in intelligent computational sciences
Guest editors: Shailesh Tiwari, Munesh Trivedi and Mohan L. Kohle
Article type: Research Article
Authors: Gupta, Ranua; * | Pachauri, Rahulb | Singh, Ashutoshc
Affiliations: [a] Department of Electronics and Communication, Jaypee University of Engineering and Technology, Raghogarh, Guna (M.P.), India | [b] Department of Computer Science, Jaypee University of Engineering and Technology, Raghogarh, Guna (M.P.), India | [c] Department of Electronics and Communication, Thapar Institute of Engineering and Technology University, Patiala, India
Correspondence: [*] Corresponding author. Ranu Gupta, Department of Electronics and Communication, Jaypee University of Engineering and Technology, Raghogarh, Guna (M.P.), 473226, India. E-mail: ranu.gupta@juet.ac.in.
Abstract: A linear method based on local statistical parameters of the image to remove the speckles of ultrasound carotid artery medical image is presented in this article. Speckle is the main drawback of medical images and it should be removed before any further processing of images like edge detection and registration. The focus of this article is to filter the speckle efficiently and effectively even at higher density of noise. The filter is designed by keeping in mind that the local statistical parameters are important rather than global statistical parameters. The weighting factor is designed such that it is high for similar areas and thus results into more smoothing without destroying the useful information, whereas it is low at the edges and thus less smoothing will be done. The filter is applied with the help of 5×5 sliding window. The noise ranging from 0.01–0.09 of variance is unnaturally inserted in the medical images through Matlab. The efficiency calculating parameters like Signal to Noise Ratio (SNR), Quality Index (Q), Mean Square Error (MSE), Similarity Index Measure (SSIM) and Edge Preserved Index (EPI) were used to evaluate the proposed technique. The suggested method is also compared with the existing local statistical mean variance filter for the said parameters in order to analyse the performance of the filter.
Keywords: Medical images, ultrasound, speckle, local statistics
DOI: 10.3233/JIFS-169715
Journal: Journal of Intelligent & Fuzzy Systems, vol. 35, no. 2, pp. 1807-1816, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl