Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Liu, Hongliang* | Gao, Shuguo | Sun, Lu | Tian, Yuan
Affiliations: Electric Power Research Institute of State Grid Hebei Electric Power Co., Ltd., Shijiazhuang, Hebei, China
Correspondence: [*] Corresponding author: Hongliang Liu, Electric Power Research Institute of State Grid Hebei Electric Power Co., Ltd., Shijiazhuang, Hebei 050021, China. E-mail: lhl1606999785@163.com.
Abstract: During the transformer winding deformation process, the leakage magnetic field around the winding will change accordingly. Therefore, it is an effective method to monitor and track the change of the leakage magnetic field and then analyze and judge the state of the transformer. This paper firstly uses Comsol Multiphysics software to establish a 110 kV transformer electromagnetic simulation calculation model. Based on the simulation results of magnetic leakage distribution, an installation plan for the internal magnetic leakage sensor of a 110 kV true transformer is determined. The measurement results of the true single short-circuit test under different working conditions verify the accuracy of the simulation model. Subsequently, a number of B-phase high-centered three-phase short circuit (H-M B) true type tests were carried out, and the relationship between the magnetic leakage distribution characteristics and the impedance change rate after each impact was analyzed. The results show that before the transformer is seriously deformed due to multiple short circuit shocks, the sensitivity of the impedance change rate to the winding deformation is low, and the first five shocks only increase from 0.11% to 0.39%. However, the difference ratio between the simulation value and the test value of magnetic flux leakage (MFL) has obvious changes in each small deformation. BX3 increases from 1.77% to 5.62%, and BX4 increases from 2.08% to 6.55%. The difference ratio of four shocks before winding deformation is more than 6%. Therefore, by monitoring the flux leakage magnetic induction intensity, when the difference ratio is greater than 6%, strengthen the vigilance, which can provide a certain basis for winding monitoring before serious deformation.
Keywords: Transformer, comsol, magnetic leakage sensor, magnetic flux leakage intensity, deformation monitoring
DOI: 10.3233/JCM-226656
Journal: Journal of Computational Methods in Sciences and Engineering, vol. 23, no. 3, pp. 1517-1528, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl