Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Czaprowski, Dariusza; b; * | Kolwicz, Aleksandrab | Afeltowicz, Annab | Pawƚowska, Paulinab | Oleksy, Lukaszc
Affiliations: [a] Department of Rehabilitation, Józef Piƚsudski University of Physical Education, Warsaw, Poland | [b] Department of Physiotherapy, Józef Rusiecki University College, Olsztyn, Poland | [c] Academy of Physical Education, Kraków, Poland
Correspondence: [*] Corresponding author: Dariusz Czaprowski, Department of Rehabilitation, Józef Piƚsudski University of Physical Education, Marymoncka 34, 00-968 Warsaw, Poland. Tel./Fax: +22 834 04 31, ext. 503; E-mail:dariusz.czaprowski@interia.pl
Abstract: BACKGROUND: The surface electromyography (sEMG), by evaluating the paraspinal muscle activity, may be used for diagnosis and evaluation of rehabilitation effectiveness patients with low back pain. OBJECTIVE: The purpose of the study was to determine the intra- and inter-session reliability of the measurement of the activity of the lumbar erector spinae (LES) activity (extension-flexion ratio). METHODS: The study included 21 asymptomatic subjects, aged 14 to 27 years, mean 23.7 ± 2.9. The LES muscle activity was assessed with using of the sEMG during forward trunk flexion and extension by two examiners. Based on the quotient of the LES muscle activity obtained during four concentric and eccentric tasks the extension-flexion ratio was calculated. RESULTS: The measurements displayed excellent or fair-to-good reliability (intraclass correlation coefficient ranged from 0.90 to 0.68). The typical error and coefficient of variations, ranged from 0.34 to 0.58, and from 13.7 to 21.9, respectively. CONCLUSIONS: The measurement of the extension-flexion ratio performed with the use of sEMG shows high level of intra- and inter-session reliability, suggesting that this parameter is a reliable tool in evaluation of the lumbar paraspinal muscles activity. However, the level of typical error should be taken into account.
Keywords: Reliability, typical error, surface electromyography, extension-flexion ratio
DOI: 10.3233/BMR-150590
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 28, no. 4, pp. 827-832, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl