Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: An, Da-Ina | Park, Jung-Euna | Lee, Chang-Hyungb | Kim, Soo-Yonga; *
Affiliations: [a] Department of Physical Therapy, Pusan National Yangsan Hospital, Yangsan, Gyeongsangnam-do, Korea | [b] Research Institute for Convergence of Biomedical Science and Technology Physical Medicine and Rehabilitation, Pusan National Yangsan Hospital, Yangsan, Gyeongsangnam-do, Korea
Correspondence: [*] Corresponding author: Soo-Yong Kim, Department of Physical Therapy, Pusan National Yangsan Hospital, 20 Geumo-ro, Mulgeum-eup, Yangsan-si, Gyeongsangnam-do, 50612, Korea. Tel.: +82 55 360 4214; Fax: +82 55 360 4242; E-mail: gasigogi11@naver.com.
Abstract: BACKGROUD: Reliable scapular upward rotation and anterior-posterior tilt data are required for patients with subacromial impingement syndrome (SIS). Only a few studies have explored the reliability of such measurements derived using a modified inclinometer. OBJECTIVES: To determine the relative and absolute reliability of scapular upward rotation and anterior-posterior tilt measurements derived using a modified digital inclinometer in patients with SIS. METHOD: Seventeen SIS patients were assessed twice within 1 week. We determined the relative and absolute measurement reliability by calculating the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal clinically important difference (MCID). Both intra- and interrater reliability were determined. RESULTS: The intra-rater reliability (both measurements) was high (0.72–0.88), and the interrater ICC was high to excellent (0.72–0.98). Clinically acceptable SEM and MCID values were obtained for scapular upward rotation (SEM: 4.28–9.33∘, MCID: 5.1–11.3∘) and anterior-posterior tilt (SEM: 3.72–7.55∘, MCID: 2.5–10.8∘). CONCLUSIONS: Measurements of scapular upward rotation and anterior-posterior tilt using a modified digital inclinometer reliably reveal scapular position and kinematics in patients with SIS.
Keywords: Modified digital inclinometer, scapular anterior-posterior tilt, scapular upward rotation, subacromial impingement syndrome
DOI: 10.3233/BMR-200080
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 34, no. 5, pp. 837-843, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl