Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Babaee, Tahera | Kamyab, Mojtabaa; * | Ahmadi, Amirb | Sanjari, Mohammad Alic | Ganjavian, Mohammad Salehd
Affiliations: [a] Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran | [b] Department of Physiotherapy, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran | [c] Biomechanics Lab, Rehabilitation Research Center, Department of Rehabilitation Basic Sciences, School of Rehabilitation, Iran University of Medical Sciences, Tehran, Iran | [d] Department of Orthopaedic Surgery, Shafa Yahyaiian hospital, Iran University of Medical Sciences, Tehran, Iran
Correspondence: [*] Corresponding author: Mojtaba Kamyab, Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, Iran University of Medical Sciences, Madadkaran Avenue, Shahnazari St., Madar Square, Mirdamad Blvd., Tehran, Iran. Tel.: +98 21 2222 0947 (Ext 255); Fax: +98 21 2222 0946; E-mail: kamyab.m@iums.ac.ir.
Abstract: BACKGROUND: There is a lack of evidence in reliability of the modified sphygmomanometer to measure the brace-interface pad pressure in adolescents with Scheuermann’s kyphosis (SK). OBJECTIVES: To evaluate the intra- and inter-observer reliability of modified sphygmomanometer for measuring interface pad pressure in the Milwaukee brace. METHODS: Two observers measured the pressure of the shoulder and kyphosis pads in Milwaukee brace on 33 adolescents with SK with an average age of 14.67 ± 1.72 years and Cobb angle 64.48∘± 7.53∘. All measurements were obtained in one day. The measurements were done in the inhalation and exhalation of tidal breathing during standing and sitting positions. The intraclass correlation coefficient (ICC), 95% confidence interval (CI), and linear mixed model ANOVA effects were calculated. RESULTS:The intra-observer reliability varied from a good ICC of 0.81 (0.66–0.90) to an excellent of 0.97 (0.95–0.98). The inter-observer reliability also varied from a good ICC of 0.82 (0.67–0.91) to an excellent of 0.96 (0.93–0.98). The linear mixed model ANOVA analysis showed that the rater, position, and breathing had a significant effect on the pad pressure measurements. CONCLUSIONS:The modified sphygmomanometer is a reliable tool to measure the pad pressure of the Milwaukee brace for adolescents with SK.
Keywords: Pressure measurement, brace, Scheuermann’s kyphosis, sphygmomanometer, reliability
DOI: 10.3233/BMR-171041
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 32, no. 4, pp. 647-654, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl