Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Case Report
Authors: Guan, Xiaofei | Zhao, Shan | Gu, Xin | Zhang, Hailong | He, Shisheng*
Affiliations: Department of Orthopedics, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai 200072, China
Correspondence: [*] Corresponding author: Shisheng He, Department of Orthopedics, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Yanchang Road 301, Shanghai 200072, China. Tel.: +86 21 66307330; Fax: +86 21 66307046; E-mail:tjspinecenter@163.com
Note: [1] These authors contributed equally to this work.
Abstract: OBJECTIVE: To present a unique case of guide wire breakage as a rare complication during posterolateral endoscopic lumbar discectomy. BACKGROUND: Posterolateral endoscopic lumbar discectomy (PELD) has become a routinely performed minimally invasive spinal procedure. However, several complications of PELD have attracted our concerns, including the intraoperative injury to neural and vascular structures and failure of the surgery. We have countered a rare intraoperative complication of guidewire breakage during a PELD procedure, as far as we know, this has not been reported previously, and we wish to draw attention to this hazard. METHODS: The medical records, operative reports, and radiographical imaging studies of a single patient were retrospectively reviewed. RESULTS: A 28-year-old man presented with right posterior sciatica for 3 months was admitted to the hospital. Unsatisfactory improvement was observed under supervised conservative treatment. Preoperative magnetic resonance imaging (MRI) showed a disc herniation at the L4-L5 level. After preoperative evaluation, a PELD procedure was performed with local anesthesia. After advancement of guide wire and discography, the guiding rod was found not in the vicinity of the extruding disc fragment. Therefore, the operator tried to redirect the guiding rod. However, after several attempts, the guide wire was broken in the disc fragment under imaging. With the patient's permit, the operator inserted the working cannula to the broken end of guide wire and retrieved it using straightened grasping forceps. Then foraminotomy and fragmentectomy were accomplished under endoscope. The patient made uneventful recovery and was free of symptoms for the following 6 months. CONCLUSIONS: In conclusion, the guide wire breakage during PELD procedures is a rare but a serious complication. An appropriate manner and operation is very important to prevent this complication. Once it does occur, the remnant of the guide wire can possibly be retrieved under endoscope with great experience. However, as for the beginners, a transfer to open operation is suggested to prevent new complications.
Keywords: Endoscopic discectomy, case report, intraoperative complication, instrument breakage, working zone, minimally invasive surgery
DOI: 10.3233/BMR-150295
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 30, no. 2, pp. 383-386, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl