Article type: Research Article
Authors: Seidi, Foada; * | Minoonejad, Hoomana | Youdas, James W.b
Affiliations: [a] Department of Health and Sport Medicine, University of Tehran, Tehran, Iran | [b] Physical Therapy, Mayo Clinic, College of Medicine, Rochester, MN, USA
Correspondence: [*] Corresponding author: Foad Seidi, Department of Health and Sport Medicine, University of Tehran, Kargare Shomali St, P.O.B: 1439813117, Tehran, Iran. Tel.: +98 216 111 8928; Fax: +98 218 822 5482; E-mail: foadseidi@ut.ac.ir
Abstract: Background and Objective:The amount of postural sway and sagittal deviation of lumbar lordosis angle in measurements of standing lumbar curvature obtained by flexible curve can be decreased when using a spine stabilizer instrument. However, this assumption has not been investigated so far. This study aims to determine the effect of using a spine stabilizer instrument on the validity, reliability, and standard errors of measurement of flexible curve in the standing lumbar curvature measurements. Material and Method:Thirty-four volunteer men aged between 19 and 30 years participated in the study By using a 50-cm flexible curve, with and without spine stabilizer instrument, and a lumbar simple lateral radiograph (LSLR), the standing lumbar curvature was measured by three methods for each subject. These methods were called A, B and C, respectively. Results:By using the Pearson’s correlation analysis at significance level of 0.05, the coefficient of correlation between standing lumbar curvature measurements in methods A and B with C were 0.95 and 0.84, respectively. In addition, the intraclass correlation coefficient for methods A and B were 0.94 and 0.79, respectively. Also, results of the one-way analysis of variance for comparison of pairs indicated a significant difference in the mean values of standing lumbar curvature angles between methods B and C. Conclusions:Results indicated the flexible curve was an appropriate instrument for standing lumbar curvature measurements. Using spine stabilizer instrument to control postural sway increases the validity and reliability of flexible curve method and decreases its standard errors of measurement.
Keywords: Spine stabilizer instrument, postural sway, standing lumbar curvature, flexible curve
DOI: 10.3233/BMR-140521
Journal: Journal of Back and Musculoskeletal Rehabilitation, vol. 28, no. 2, pp. 311-316, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl