Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Chen, Wei; | Sonntag, Christoph | Boesten, Freek | Oetomo, Sidarto Bambang; | Feijs, Loe
Affiliations: Department of Industrial Design, Eindhoven University of Technology, Den Dolech 2, 5612 AZ, Eindhoven, The Netherlands. E-mail: w.chen@tue.nl, f.boesten@student.tue.nl, l.m.g.feijs@tue.nl | Department of Electrical Engineering, Eindhoven University of Technology, Den Dolech 2, 5612 AZ, Eindhoven, The Netherlands. E-mail: c.sonntag@tue.nl | Neonatal Intensive Care Unit, Máxima Medical Center, PO Box 7777, 5500 MB, Veldhoven, The Netherlands. E-mail: s.bambangoetomo@mmc.nl
Note: [] Corresponding author.
Abstract: Continuous monitoring of health parameters is crucial for preterm new born babies admitted at the neonatal intensive care unit (NICU) in hospitals. The critically ill neonates are extremely tiny and vulnerable to external disturbance. In the context of ambient intelligence and smart environments, non-invasive health monitoring with wearable sensors is promising for the survival of these neonates and the quality of their life later on. A key question for health monitoring with wearable sensors is how to obtain reliable electrical power for the sensors, signal amplifiers, filters and transmitters. In this paper, we propose a design of wireless power supply based on the principle of inductive contactless energy transfer for use in NICU. The design process consists of scientific and user research, idea generation and selection, proof of technology, prototype implementation, and experimental validation. The proposed power supply satisfies the requirements of neonatal monitoring and provides continuous power when the neonate is inside the incubator or during Kangaroo mother care. A prototype is designed and implemented to demonstrate the performance of the power supply and the possibilities for aesthetic features. Experimental results show that the prototype transfers approximately 840 mW of power.
Keywords: Neonatal monitoring, inductive contactless energy transfer, wearable sensors, design process
DOI: 10.3233/AIS-2009-0022
Journal: Journal of Ambient Intelligence and Smart Environments, vol. 1, no. 2, pp. 185-196, 2009
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl