Article type: Research Article
Authors: García Barrado, Leandroa | Coart, Elsb; * | Vanderstichele, Hugo M.J.c | Burzykowski, Tomasza; b
Affiliations: [a] Interuniversity Institute for Biostatistics and statistical Bioinformatics (I-BioStat), Hasselt University, Diepenbeek, Belgium | [b] International Drug Development Institute (IDDI), Louvain-la-Neuve, Belgium | [c] ADx NeuroSciences, Gent, Belgium
Correspondence: [*] Correspondence to: Els Coart, International Drug Development Institute (IDDI), Avenue Provinciale 30, 1340 Louvain-la-Neuve, Belgium. Tel.: +32 10 61 44 44; Fax: +32 10 61 88 88; E-mail: Elisabeth.Coart@iddi.com
Abstract: Current technologies quantifying cerebrospinal fluid biomarkers to identify subjects with Alzheimer’s disease pathology report different concentrations in function of technology and suffer from between-laboratory variability. Hence, lab- and technology-specific cut-off values are required. It is common practice to establish cut-off values on small datasets and, in the absence of well-characterized samples, to transfer the cut-offs to another assay format using ‘side-by-side’ testing of samples with both assays. We evaluated the uncertainty in cut-off estimation and the performance of two methods of cut-off transfer by using two clinical datasets and simulated data. The cut-off for the new assay was transferred by applying the commonly-used linear regression approach and a new Bayesian method, which consists of using prior information about the current assay for estimation of the biomarker’s distributions for the new assay. Simulations show that cut-offs established with current sample sizes are insufficiently precise and also show the effect of increasing sample sizes on the cut-offs’ precision. The Bayesian method results in unbiased and less variable cut-offs with substantially narrower 95% confidence intervals compared to the linear-regression transfer. For the BIODEM datasets, the transferred cut-offs for INNO-BIA Aβ1-42 are 167.5 pg/mL (95% credible interval [156.1, 178.0] and 172.8 pg/mL (95% CI [147.6, 179.6]) with Bayesian and linear regression methods, respectively. For the EUROIMMUN assay, the estimated cut-offs are 402.8 pg/mL (95% credible interval [348.0, 473.9]) and 364.4 pg/mL (95% CI [269.7, 426.8]). Sample sizes and statistical methods used to establish and transfer cut-off values have to be carefully considered to guarantee optimal diagnostic performance of biomarkers.
Keywords: Alzheimer’s disease, Bayesian method, biomarker cut-off value, diagnostic accuracy
DOI: 10.3233/JAD-150511
Journal: Journal of Alzheimer's Disease, vol. 49, no. 1, pp. 187-199, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl