Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Cagnin, Annachiaraa; b; * | Simioni, Mariachiaraa | Tagliapietra, Matteoa | Citton, Valentinab | Pompanin, Saraa | Della Puppa, Alessandroc | Ermani, Marioa | Manara, Renzod
Affiliations: [a] Department of Neurosciences, University of Padova, Padova, Italy | [b] IRCCS San Camillo Hospital Foundation, Venice, Italy | [c] Neurosurgical Unit, Padova Hospital, Padova, Italy | [d] Neuroradiology, Section of Neurosciences, University of Salerno, Salerno, Italy
Correspondence: [*] Correspondence to: Annachiara Cagnin, MD, Department of Neurosciences, University of Padova Medical School, Via Giustiniani 5, 35128 Padova, Italy. Tel.: +39 49 8213600; Fax: +39 49 8751770; annachiara.cagnin@unipd.it
Abstract: Background: Idiopathic normal-pressure hydrocephalus (iNPH) can resemble or occur in combination with other brain disorders frequently present in the elderly such as Alzheimer’s disease (AD) and dementia with Lewy bodies (DLB). Objective: To study the accuracy of a simplified callosal angle measure in differentiating iNPH from DLB and AD using conventional brain MRI. Methods: 76 patients (24 iNPH, 30 DLB, 22 AD) and 40 healthy controls served as discovering cohort. The callosal angle measure was obtained on standard coronal brain MRI images crossing the corpus callosum midpoint. 41 patients (21 iNPH and 20 DLB/AD) were used as independent validation cohort. A set of other conventional MRI markers of iNPH was also evaluated. Results: iNPH showed a significantly decreased mean callosal angle value compared to both disease groups and controls (iNPH = 109±9; DLB = 136.9±8.2; AD = 135.4±11.3; Controls = 138.5±5.2; p < 0.00001). Using a cut off angle of 123, derived by the mean -3SD of the control group, an accuracy of 96% (sensitivity 100% , specificity 95.4% ) was obtained. By ROC analysis, the area under the curve was 0.99 (95% CI: 0.97–1). The measure was consistent (intra-rater: r = 0.94) and reproducible (inter-rater: r = 0.89). In the validation cohort, this cut off angle value discriminated iNPH from DLB/AD with 97.5% accuracy. None of the conventional MRI signs reached the same accuracy. Conclusions: This simplified callosal angle measure represents an accurate, reproducible, and easy marker of iNPH.
Keywords: Alzheimer’s disease, dementia with Lewy bodies, idiopathic normal-pressure hydrocephalus, MRI marker
DOI: 10.3233/JAD-150107
Journal: Journal of Alzheimer's Disease, vol. 46, no. 4, pp. 1033-1038, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl