Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Marcori, Alexandre J.* | Moura, Túlio B.M.A. | Okazaki, Victor H.A.
Affiliations: Tutorial Education Program, Laboratory of Research and Teaching on Biomechanics, Londrina State University, Londrina, Paraná, Brazil
Correspondence: [*] Corresponding author: Alexandre Jehan Marcori, Rua Roberto Júlio Roehrig, 320, Londrina, Paraná, Brazil. Tel.: +55 43 9677 5877/43 3342 9746; E-mail:alexandremarcori@gmail.com
Abstract: BACKGROUND: Varying exercise parameters, such as angles of movement, can cause different activation patterns within muscle compartments. Therefore, it is expected that feet positioning variations could influence gastrocnemius activity. OBJECTIVE: Compare gastrocnemius activation during plantar flexion with feet pointing forwards (FO), inwards (IN) and outwards (OU). METHODS: Sixteen physically active men (21 ± 2 years; 1.75 ± 0.06 meters and 74.8 ± 7.2 kg), performed 3 sets of 10 repetitions in each of the following experimental conditions: plantar flexion with feet pointing FO, IN and OU. The root mean square (RMS) of the muscular activation of both gastrocnemius heads was analyzed in each set by electromyography. RESULTS: For the medial head of the gastrocnemius, the OU condition presented greater RMS values when compared to the IN (z = 3.41; p < 0.001) and FO (z = 2.37; p≤ 0.017) conditions. For the lateral head, however, the IN condition demonstrated greatest RMS when compared with OU (z = 3.20; p = 0.001) and FO (z = 3.25; p = 0.001) conditions. CONCLUSIONS: These results suggest that it is possible to create greater activation sites in the gastrocnemius. Trainers and practitioners could use this to prescribe exercise more efficiently, possibly correcting asymmetries in athletes, especially bodybuilders.
Keywords: Heel raise, electromyography, biomechanical specificity
DOI: 10.3233/IES-160654
Journal: Isokinetics and Exercise Science, vol. 25, no. 2, pp. 121-125, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl