Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Intziegianni, Konstantinaa; * | Cassel, Michaela | König, Niklasb | Müller, Steffena | Fröhlich, Katjaa | Mayer, Franka
Affiliations: [a] University Outpatient Clinic, Sports Medicine and Sports Orthopaedics, University of Potsdam, Potsdam, Germany | [b] Department of Health Science and Technology, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
Correspondence: [*] Corresponding author: Konstantina Intziegianni, University Outpatient Clinic, Sports Medicine and Sports Orthopaedics, University of Potsdam, Am Neuen Palais 10, Haus 12, 14469 Potsdam, Germany. Tel.: +49 331 9771640; Fax: +49 331 9771296; E-mail:intziegi@uni-potsdam.de
Abstract: BACKGROUND: Reproducible measurements of tendon structural properties are a prerequisite for accurate diagnosis of tendon disorders and for determination of their mechanical properties. Despite the widely used application of Ultrasonography (US) in musculoskeletal assessment, its operator dependency and lack of standardization influences the consistency of the measurement. OBJECTIVE: To evaluate the intra-rater reproducibility of a standardized US method assessing the structural properties of the Achilles tendon (AT). METHODS: Sixteen asymptomatic participants were positioned prone on an isokinetic dynamometer with the knee extended and ankle at 90° flexion. US was used to assess AT-length, cross-sectional area (CSA), and AT-elongation during isometric plantarflexion contraction. The intra-rater reproducibility was assessed by ICC (2.1), Test-Retest Variability (TRV, %), Bland-Altman analyses (Bias ± LoA [1.96*SD]), and Standard-Error of Measurement (SEM). RESULTS: Measurements of AT-length demonstrated an ICC of 0.93, TRV of 4.5 ± 3.9%, Bias ± LoA of -2.8 ± 25.0 mm and SEM of 6.6 mm. AT-CSA showed an ICC of 0.79, TRV of 8.7 ± 9.6%, Bias ± LoA of 1.7 ± 19.4 mm2 and SEM of 5.3 mm2. AT-elongation revealed an ICC of 0.92, TRV of 12.9 ± 8.9%, Bias ± LoA of 0.3 ± 5.7 mm and SEM of 1.5 mm. CONCLUSIONS: The presented methodology allows a reproducible assessment of Achilles tendon structural properties when performed by a single rater.
Keywords: Ultrasonography, Achilles tendon, reproducibility, isokinetic
DOI: 10.3233/IES-150586
Journal: Isokinetics and Exercise Science, vol. 23, no. 4, pp. 263-270, 2015
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl