Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Hellwig, Evan V.a; * | Perrin, David H.b
Affiliations: [a] Department of Health and Physical Education, Cedarville College, P.O. Box 601, Cedarville, OH 45314, USA | [b] Cuny School of Education, University of Virginia, Charlottesville, Virginia, USA
Note: [*] Corresponding author.
Abstract: The purpose of this study was to determine the reliability of the Kinetic Communicator's (Kin-Com) gravity correction procedure. To determine mechanical reliability, gravity correction was performed at 11 different angles while weights (1.15, 2.30, 3.45 and 4.60 kg) were suspended from the lever arm. Intrac1ass correlation (ICC) between trials showed that the Kin-Com was able to gravity correct weights with high reliability (R = 0.961–0.999). Gravity correction values from the 11 angles were analyzed with a one-way analysis of variance with repeated measures to determine if differences existed between gravity correction values collected at different angles for each weight condition. Even though reliability was good for each angle, gravity correction values collected near the vertical position differed from the gravity correction values collected at the horizontal position (P < 05). Differences decreased as weight increased. To determine clinical reliability, 25 subjects (age = 21.0 years, height = 16.6 cm, weight = 59.8 kg) were also gravity corrected in both the seated and prone positions at six different angles on 2 separate days. Correlation analysis between days showed good reliability (R = 0.83) for both positions when subjects were corrected at the horizontal. Reliability decreased as the lever arm approached vertical. Differences between gravity correction values existed at every angle measured for both positions. Even though the gravity correction was shown to be reliable at positions other than the horizontal, gravity correction should be performed at the horizontal position each time subjects are assessed.
Keywords: Gravity correction, Reliability via positions
DOI: 10.3233/IES-1995-5205
Journal: Isokinetics and Exercise Science, vol. 5, no. 2, pp. 85-91, 1995
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl