Abstract: This study compared the test results from two spinal isokinetic dynamometers, the Cybex TEF and the Cybex 6000-TMC (Cybex, Ronkonkoma, NY) in an effort to establish the measurement reliability of the latter device and to develop formulas for the interconversion of test results. A stratified random sample of 5,760 normal subjects (2,880 females, 2,880 males; mean age 25.0±9.9 years; age range 17–49 years) was tested on both devices under an alternate repeated-measures paradigm across the concentric isokinetic speeds of 30, 60, 90, and 120 deg/sec after standardized warmup procedures. Data for peak torque expressed as a percentage of body weight was collected from five maximal repetitions of spinal flexion and extension at all test speeds and then subjected to multiple statistical analyses. Results showed a high level of measurement reliability for both the TEF (intraclass correlation [ICC] = 0.927) and the TMC (ICC = 0.910); failed to show significant differences in subject performances across devices, speeds, genders, and motions; and showed comparison formulas of TEF = TMC + 13.325, TEF = TMC + 15.225, TEF = TMC + 15.775, and TEF = TMC + 16.775 for female and male spinal flexion and extension, respectively. The results may be useful for the design of clinical programs that include spinal isokinetic testing procedures.
Keywords: Spinal isokinetics, isokinetic testing, spinal muscle strength, clinical instrumentation
DOI: 10.3233/IES-1994-4305
Journal: Isokinetics and Exercise Science, vol. 4, no. 3, pp. 112-115, 1994
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl