Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Stam, H. J.a; *; ** | Binkhorst, R. A.a; *** | van Nieuwenhuyzen, J. F.a; ****
Affiliations: [a] Department of Rehabilitation Medicine and Physical Therapy, Erasmus University Rotterdam, and Department of Physiology, Catholic University Nijmegen, The Netherlands
Note: [*] Head, Department of Rehabilitation Medicine and Physical Therapy, Erasmus University Rotterdam, The Netherlands.
Note: [**] Address reprint requests to Dr. H. J. Stam, Department of Rehabilitation Medicine and Physical Therapy, Erasmus University Rotterdam, P.O. Box 1738,3000 DR Rotterdam, The Netherlands.
Note: [***] Department of Physiology, Catholic University Nijmegen, The Netherlands.
Note: [****] Physiotherapist, Department of Rehabilitation Medicine and Physical Therapy, Erasmus University Rotterdam, The Netherlands.
Abstract: The purpose of this study was to establish the reliability of isometric and isokinetic torque measurements of the knee extensors in healthy volunteers assessed on the Quadriceps Dynamometer. The subjects (18 men, 16 women) were tested on three occasions, at 1-week intervals, with three different angular velocities (0, 45, and 90 deg/sec). The mean absolute torque values (range 103–206 Nm) and coefficients of variation (range 15–24%) of the knee extensors were comparable with data obtained by other investigators using a Cybex II. Interindividual variability was considerable (13–20%), as had been expected. The maximum intraindividual variability was 11%. An analysis of variance showed substantial differences within the subjects on subsequent weeks and at the different testing speeds. These results suggest that a variability of about 10% is accounted for by individual changes in torque within healthy subjects. It is to be expected that intra individual variability will be greater for patients than for healthy subjects. These data can therefore be relevant for patients in determining the reliability of strength measurements in neuromuscular disorders or in strength training.
Keywords: Knee extensors, muscle performance, measurement
DOI: 10.3233/IES-1994-4203
Journal: Isokinetics and Exercise Science, vol. 4, no. 2, pp. 64-69, 1994
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl