Authors: McGirr, Brian T.a | Martin, Jake L.b | Colborn, Chris E.a | Shefflette, Alex C.S.a | Soltysiak, Steve R.a | Dichiara, Elisabeth J.a | Caruso, John F.a; b; *
Affiliations: [a] Exercise Physiology Program, The University of Louisville, Louisville, KY, USA | [b] Exercise Physiology Program, The University of Tulsa, Tulsa, OK, USA
Correspondence: [*] Corresponding author: John F. Caruso, Exercise Physiology Program, The University of Louisville; and The University of Tulsa, 2100 S Floyd St., Louisville KY 40208, USA. Tel.: +1 502 8526648; E-mail: john.caruso@louisville.edu.
Abstract: BACKGROUND: Ultrasound is an important tool to diagnose many clinical conditions. Yet hand-held devices may be prone to more data variability in part from the greater likelihood of human error. OBJECTIVE: Quantify intra-rater reliability of subcutaneous skin fold thickness from a hand-held ultrasound device. PARTICIPANTS: College-age subjects (18 men, 14 women) submitted to two sets of ultrasound subcutaneous skin fold measurements spaced (mean + sem) 10.6 + 2.2 days apart. Per measurement, they stood relaxed as ultrasound measured the subcutaneous skin fold thickness that covered their left leg’s calf muscle group. Measurements occurred with a hand-held device (BodyMetrix Pro System BX2000; Livermore, CA) used in accordance with the manufacturer’s guidelines. Four subcutaneous measurements were made 90∘ apart (anterior, medial, posterior, lateral) at the portion of the left calf with the largest circumference. To assess intra-rater reliability, we used intraclass correlation coefficients, limits of agreement, coefficient of variation and the smallest real difference. RESULTS: Intra-rater reliability was high for most of our statistical tests. CONCLUSION: Despite the relatively long period between measurements, our hand-held ultrasound device exhibited a high degree of intra-rater reliability. Given our results, ultrasound measurements may be a useful tool to quantify skin fold thickness.
Keywords: Intraclass correlation coefficients, variability, BodyMetrix Pro System BX2000
DOI: 10.3233/IES-210157
Journal: Isokinetics and Exercise Science, vol. 30, no. 4, pp. 293-301, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl