Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Fleshman, Sue A.a; * | Keppler, Mark V.a
Affiliations: [a] Bucknell University
Note: [*] Address reprint requests to Sue A. Fleshman at 206 Cherie Down Lane, Cape Canaveral, FL 32920.
Abstract: The reliability of the specially adapted Orthotron KT-II, with stress indicators, has been examined as compared with the Cybex II, which is the established mechanism for isokinetic testing of the knee. Two testing speeds were used with the HUMAC/software system for each machine: 60 deg/sec, and 240 deg/sec. Forty-four healthy men and women, both athletes and nonathletes, with no previous knee injuries, were selected from a university population. Subjects were randomly assigned to one of two groups. Subjects tested once on each machine, with at least a 48-hour recovery period between testing sessions. A two-way analysis of variance was conducted for type of machine and order of machine testing. Sample means for nine measurements of muscular performance, selected from the Humac menu, were compared. What may be significant clinical and statistical differences were found in four of the measurements: (1) work per repetition to body weight ratio; (2) fatigue index; (3) force decay; and (4) total range of motion. Due to problems in achieving proper joint-axis alignment on the Orthotron KT-II, as compared with the Cybex II, position parameters were manipulated mathematically such that both machines had the same zero baseline for reference. Significant amounts of variance were attributed to differences in height, weight, sex, and activity status among subjects in the two groups. The inherent differences between a mechanical hydraulic system such as the Orthotron KT-II, compared with an electrically powered system such as the Cybex II seemed to be most evident in the measurement of fatigue index. Test scores on the Orthotron KT-II tended to show less fatigue than the Cybex II over the same test interval. All other measurements of muscular performance showed insignificant differences between the sample means on the two machines.
Keywords: Orthotron KT-II, software analysis, comparison to Cybex II
DOI: 10.3233/IES-1992-2408
Journal: Isokinetics and Exercise Science, vol. 2, no. 4, pp. 195-203, 1992
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl