Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kwon, Yong Unga; * | Blaise Williams, D.S.b
Affiliations: [a] School of Physical Education, Recreation, and Health, Athletic Training Program, Kean University, Union, NJ, USA | [b] Nike Sports Research Lab, Nike, Inc, Beaverton, OR, USA
Correspondence: [*] Corresponding author: Yong Ung Kwon, School of Physical Education, Recreation, and Health, Athletic Training Program, Kean University, Union, NJ, USA. Tel.: +1 336 558 1336; E-mail: mugika2@gmail.com.
Abstract: BACKGROUND: There have been conflicting findings regarding the relationship between ankle muscle fatigue and a fatiguing run due to different selections of running protocol. Bruce protocol is strongly established as a maximum graded exercise test for volitional fatigue. OBJECTIVE: To determine if volitional exhaustion utilizing the Bruce protocol would result in localized ankle plantarflexor (PF) and dorsiflexor (DF) fatigue. METHODS: Twenty-three healthy individuals participated. Participants ran on a treadmill until they reached volitional exhaustion during performance of the Bruce protocol. Before and after volitional exhaustion, participants performed 3 maximum voluntary isometric contractions for both PF and DF with electromyography (EMG) assessing activation of the tibialis anterior, peroneus longus, and medial gastrocnemius muscles. RESULTS: Volitional exhaustion resulted in ankle PF fatigue (moment: p< 0.001), ankle DF fatigue (moment: p< 0.001), median frequency (p= 0.021) and mean amplitude (p< 0.001) of the tibialis anterior (TA). CONCLUSIONS: That the general fatigue induced by the Bruce protocol caused ankle PF and DF fatigue. Identifying and understanding the neuromuscular responses to volitional fatigue following running are helpful in not only improving the comfort and enjoyment of physical activities, but also in enhancing training and safety of injuries associated of these activities.
Keywords: Running, maximum graded exercise test, electromyography, moment, isokinetic dynamometer
DOI: 10.3233/IES-182120
Journal: Isokinetics and Exercise Science, vol. 26, no. 3, pp. 211-218, 2018
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl