Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Lafrance, Simona | Hsu, Jimmya | Caspin, Lauraa | Yee, Bennetta | Robbins, Shawna; b | Preuss, Richarda; b; *
Affiliations: [a] School of Physical and Occupational Therapy, McGill University, Montreal, QC, Canada | [b] Constance-Lethbridge Rehabilitation Center, Research Site of the Center for Interdisciplinary Research in Rehabilitation, Montreal, QC, Canada
Correspondence: [*] Corresponding author: Richard Preuss, School of Physical & Occupational Therapy, McGill University, 3630 Promenade Sir-William-Osler, Montreal, Quebec, Canada H3G 1Y5. Tel.: +1 514 398 4400 ext. 00652; Fax: +1 514 398 8193; E-mail: richard.preuss@mcgill.ca.
Abstract: BACKGROUND: The ratio of hamstring to quadriceps strength (H/Q), from isokinetic testing, is often used to guide training or rehabilitation. OBJECTIVES: The primary objective was to develop an assessment protocol that produces reproducible H/Q data in a single testing session. METHODS: Twenty-four healthy subjects, 16 women and 8 men, were tested using a reliability study design (2 sessions, 5 repetitions). The main outcome measure was the dynamic control ratio at 60∘/s (DCR60). Testing was also done at 120∘/s, and concentrically at 180∘/s. Generalizability theory was used to determine the reliability (φ) coefficient and the minimal detectable change MDC, and to extrapolate the data to develop an optimal assessment protocol, ideally using data from only one session. RESULTS: Single-session DCR60 data were reproducible (φ coefficient = 0.868, MDC95 = 0.144) using 5 repetitions, excluding the first repetition from the average. Values were improved by averaging over multiple sessions and repetitions, although little was gained from more than 2 sessions or 5 repetitions. Comparable results were found for testing at 120∘/s. CONCLUSIONS: Reproducible DCR60 values may be derived from a single testing session of the hamstrings (in eccentric mode) and the quadriceps (in concentric mode). We recommend collecting five repetitions, and averaging the data for repetitions 2–5.
Keywords: Knee, muscle strength, rehabilitation, reproducibility, dynamometer
DOI: 10.3233/IES-172150
Journal: Isokinetics and Exercise Science, vol. 25, no. 4, pp. 263-270, 2017
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl