Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Mandalidis, D.G.a | Donne, B.b | O'Regan, M.c | O'Brien, M.a
Affiliations: [a] Department of Anatomy, | [b] Department of Physiology, | [c] Department of Statistics, Trinity College Dublin, Dublin 2, Ireland
Note: [] Avlonos 41 -- Sepolia, 104 43 -- Athens, Greece. Tel: +30 15155 309; E-mail: dmndldis@hotmail.com
Abstract: This study has investigated the reliability of an isokinetic testing protocol for the shoulder rotators in the scapular plane to estimate the minimum variation of rotator moment needed to detect a significant change between two tests. Concentric and eccentric actions of shoulder internal and external rotation were assessed in a group of 31 male students. Measurements were performed on the dominant and non-dominant sides, at 60 and 120^{\circ} \cdots^{-1}, using an isokinetic dynamometer. Each volunteer was assessed in the seated position, with the arm at 45^{\circ} of abduction and 30^{\circ} of horizontal adduction. The intraclass correlation coefficient (ICC 3,1), the standard error of measurement (SEM) and the limits of agreement (LOA) were used to determine inter-session reliability and the magnitude of the measurement error for gravity corrected peak and average moment. Moderate to high ICC values (0.76--0.93) were observed for all measured variables. The measurement error associated with repeated measures ranged between 3.9--13.3 Nm. Both SEM and LOA revealed greater measurement errors for peak compared to average moment, eccentric compared to concentric actions, and internal compared to external rotation. The findings of the present study suggested that decline or improvement in isokinetic shoulder rotator moment should only be considered as a significant response to a pathology or an intervention, when the moment data obtained in consecutive repeated measures is lower or greater than the measurement error.
Keywords: reliability, isokinetic, shoulder rotators, scapular plane
DOI: 10.3233/IES-2001-0066
Journal: Isokinetics and Exercise Science, vol. 9, no. 1, pp. 65-72, 2001
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl