Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: International Conference on Electromagnetic Fields and Applications - ICEF 2021
Guest editors: Yongjian Li
Article type: Research Article
Authors: Li, Cailiana; b | Li, Yuanyuana; | Liu, Guoqianga; b
Affiliations: [a] Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China | [b] University of Chinese Academy of Sciences, Beijing, China
Correspondence: [*] Corresponding author: Yuanyuan Li, Institute of Electrical Engineering Chinese Academy of Sciences, Beijing, China. E-mail: lyy@mail.iee.ac.cn
Abstract: Magneto-Acousto-Electrical Tomography (MAET) has the advantage of high spatial resolution and high image contrast and is expected to achieve early breast cancer diagnosis. At present, the density of biological tissue is usually assumed to be the density of water. The effect of density changes on the MAET signal has not been studied. Liposarcoma of the breast is a common malignant tumor. Unlike normal breast cancer which occurs in the gland, liposarcoma of the breast occurs in the fat of the breast. However, the fat density of the breast is widely distributed, which is different from that of liposarcoma. Therefore, it is very important to study the effect of density change on the MAET signals. In this paper, a finite element simulation model is established to consider the influence of density variation on the MAET signal. The simulation results show that an increase in density reduces the amplitude of the original MAET signal. The degree of reduction in signal amplitude is proportional to the increase in signal density. The simulation results are consistent with the theoretical analysis. Finally, the MAET experimental platform is built to validate the simulation results of MAET signals. The simulation and experiment results show that the change of density greatly influences the detection of breast liposarcoma based on MAET. It cannot be directly equivalent to the density of water. The results of this study indicate that MAET is expected to detect the early diagnosis of breast liposarcoma.
Keywords: Density, liposarcoma, MAET
DOI: 10.3233/JAE-210236
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 70, no. 4, pp. 433-443, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl