Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhang, Ziyia; | Huang, Yindonga | Liu, Peiguob; | Ding, Liangb | Cheng, Lia
Affiliations: [a] National Innovation Institute of Defense Technology, Academy of Military Science, Beijing, China | [b] College of Electronic Science and Technology, National University of Defense Technology, Changsha, China
Correspondence: [*] Corresponding authors: Ziyi Zhang, National Innovation Institute of Defense Technology, Academy of Military Science, Beijing 100071, China. E-mail: ziyizhang@nudt.edu.cn. Peiguo Liu, College of Electronic Science and Technology, National University of Defense Technology, Changsha 410073, China. E-mail: pg731@126.com
Abstract: Magnetic Induction Spectroscopy (MIS) is an emerging technique for contactless measurement of bioimpedance with promising application in intracerebral hemorrhage (ICH) detection. Here, we report numerical simulations of ICH detection based on the MIS. A novel MIS sensor using two planar rectangular spiral coils (TPRSC) as the exciter with frequency range 120 kHz-9 MHz is proposed for the first time. The exciter can generate an antisymmetric normal magnetic field at the detection sensor, and hence the primary voltage can be canceled theoretically. We construct symmetry-based and asymmetry-based ICH models with realistic anatomic structure and hexahedral discretization feature for numerical simulations. The numerical simulations based on the finite integration technique are conducted in the three-dimensional electromagnetic analysis software CST. The voltage phase spectrum, the phase change spectrum and the relative conductivity change spectrum at different hemorrhage volumes are calculated. We compare sensitivities between the TPRSC-based MIS sensor and the conventional type (CC MIS sensor) which uses the single planar rectangular spiral coil as the exciter. Using the constructed ICH models, the specific absorption rate (SAR) and the internal electric field strength are computed to evaluate the electromagnetic safety of the TPRSC-based MIS sensor. Results show that compared with the CC MIS sensor, the sensitivity of the TPRSC-based MIS sensor for measuring the voltage phase is improved by two orders of magnitude, and for measuring the phase change is improved by more than ten times. The phase change and relative conductivity change spectra for the TPRSC-based MIS sensor demonstrate good separability between different small-volume hemorrhages. In addition, the electromagnetic safety of the TPRSC-based MIS is also superior to that of the CC MIS sensor, which conforms to the IEEE standard and the ICNRP guidelines over a wide range of the amplitude of the excitation current.
Keywords: Magnetic induction spectroscopy (MIS), intracerebral hemorrhage (ICH), phase change, conductivity, head model
DOI: 10.3233/JAE-210141
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 71, no. 2, pp. 149-167, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl