Authors: Guo, Jiayia; b; | Geng, Jianghaia | Lü, Fangchenga; b
Affiliations: [a] Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding, Hebei, China | [b] State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
Correspondence: [*] Corresponding author: Jiayi Guo, Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding, Hebei Province, 071003, China; and State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China. E-mail: guojiayi@ncepu.edu.cn
Abstract: A new core vibration calculation method of UHV shunt reactors is proposed to deal with the problem that vibration parameters of the core of an ultra-high voltage (UHV) shunt reactor cannot be measured on site. A series of tests have validated that the method can calculate the vibration parameters of a UHV shunt reactor core with different voltage ratios. The method is adopted to study the influence of nodal voltage fluctuations of the UHV AC tie line on the core vibration characteristics of a UHV shunt reactor under normal and abnormal operating conditions. The conclusion is drawn as follows: in the three operating states assessed herein, no matter whether the power grid is in a normal state or not, the core of the UHV shunt reactor will not reach magnetic saturation, and the vibration parameters of the reactor always maintain a linear relationship with the operating voltage. The changes of power grid operation parameters are introduced to the research into reactor vibration, which is conducive to a more comprehensive understanding of the actual operating state of a UHV shunt reactor. It can also provide help for the design and operation of UHV shunt reactors.
Keywords: Shunt reactor, core vibration, voltage fluctuations, magnetic saturation
DOI: 10.3233/JAE-201564
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 66, no. 4, pp. 561-580, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl