Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhao, Jianhuia; b; | Yue, Pengfeia | Grekhov, Leonidb | Wei, Kebiaoa | Ma, Xiuzhena
Affiliations: [a] School of Power and Energy Engineering, Harbin Engineering University, Harbin, China | [b] College of Power Engineering, Bauman Moscow State Technical University, Moscow, Russia
Correspondence: [*] Corresponding author: Jianhui Zhao, School of Power and Energy Engineering, Harbin Engineering University, Harbin 150001, China. Tel.: +8613804531631; E-mail: zhaojianhui@hrbeu.edu.cn
Abstract: In our study, the B–H magnetization curves at temperatures between 16 and 150∘C and frequencies between 50 Hz and 1000 Hz were measured to analyse the effect of temperature and frequency on the magnetization characteristics of electrical iron DT4C. By researching a high-speed solenoid valve (HSV) for a common rail injector, the temperature and frequency dependence of DT4C and their effects on the electromagnetic force and dynamic response of a HSV were obtained. The research results showed that an increase in temperature could decrease the magnetic flux density; however, the decrease was not apparent. The effect of temperature on the relative permeability depended on the range of magnetic flux density B. The temperature dependence of DT4C was weak in the temperature range of 16--150∘C. This stability of magnetic characteristic of DT4C ensures that the dynamic response of a HSV could be maintained well for a common rail injector. Magnetization frequencies had a significant influence on the magnetization of DT4C. An increase in the frequency would delay the transition to the saturation magnetic flux density Bs. The effect of frequency on the electromagnetic force became increasingly significant as the driving current increased. In a frequency range of 50–200 Hz, the opening response time of a HSV could be maintained well. When the frequency was higher than 200 Hz, the opening time increased significantly with the frequency raised from 200 Hz to 1000 Hz, furthermore, the HSV was out of control and closed ahead of time.
Keywords: Dynamic response, magnetic B-H curve, high speed solenoid valve, common rail injector
DOI: 10.3233/JAE-180022
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 60, no. 2, pp. 173-185, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl