Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Proceedings from the 16th International Symposium on Applied Electromagnetics and Mechanics (ISEM 2013)
Guest editors: Xavier Maldague and Toshiyuki Takagi
Article type: Research Article
Authors: Desideri, Danielea; * | Cavallin, Tommasob | Maschio, Alvisea
Affiliations: [a] Department of Industrial Engineering, University of Padova, Padova, Italy | [b] Institute of Inorganic Chemistry and Surfaces, National Research Council, Padova, Italy | Université Laval, Canada | Tohoku University, Japan
Correspondence: [*] Corresponding author: Daniele Desideri, Department of Industrial Engineering, University of Padova, via Gradenigo 6/a, I-35131, Padova, Italy. Tel.: +39 04 982 775 66; Fax: +39 04 982 775 99; E-mail: daniele.desideri@dii.unipd.it
Abstract: An improved version of a coaxial sample holder with continuous inner conductor for measuring the shielding effectiveness of planar films is presented. Keeping the design idea of the previously realized version of inner conductor split in two parts that are screwed on the sample under test, new aspects are: presence of tapered transitions, compact realization, and overall small size (total length less than 150 mm; maximum diameter of the cylindrical device of 48 mm). The theoretical only TEM mode maximum frequency is about 5 GHz. The assembly of the device is easy, as it is the sample preparation. Experimental data have been get in the range 0.1 MHz–3 GHz by using a vector network analyzer. The reliability of the system has been proved by using, as reference samples, copper and aluminium thin films deposited by DC magnetron sputtering on kapton substrates. Films with different thicknesses have been prepared, with values around a few hundreds of nanometers, as measured by using a surface profiler. The shielding effectiveness experimental data of the used reference samples are reported and are well in agreement with the theoretical values.
Keywords: Coaxial sample holder, planar film, shielding effectiveness
DOI: 10.3233/JAE-141840
Journal: International Journal of Applied Electromagnetics and Mechanics, vol. 45, no. 1-4, pp. 273-278, 2014
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl