Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Special issue on Intelligent Biomedical Data Analysis and Processing
Guest editors: Deepak Gupta, Oscar Castillo and Ashish Khanna
Article type: Research Article
Authors: Kasturiwale, Hemant P.a; * | Kale, Sujata N.b
Affiliations: [a] Department of Electronics Engineering, Thakur College of Engineering and Technology, Mumbai, India | [b] Department of Applied Electronics, Sant Gadge Baba Amravati University, Amravati, India
Correspondence: [*] Corresponding author: Hemant P. Kasturiwale, Department of Electronics Engineering, Thakur College of Engineering and Technology, Mumbai, India. E-mail: hemantkasturiwale@gmail.com.
Abstract: The Autonomous Nervous System (ANS) controls the nervous system and Heart Rate Variability (HRV) can be used as a diagnostic tool to diagnose heart defects. HRV can be classified into linear and nonlinear HRV indices which are used mostly to measure the efficiency of the model. For prediction of cardiac diseases, the selection and extraction features of machine learning model are effective. The available model used till date is based on HRV indices to predict the cardiac diseases accurately. The model could hardly throw light on specifics of indices, selection process and stability of the model. The proposed model is developed considering all facet electrocardiogram amplitude (ECG), frequency components, sampling frequency, extraction methods and acquisition techniques. The machine learning based model and its performance shall be tested using the standard BioSignal method, both on the data available and on the data obtained by the author. This is unique model developed by considering the vast number of mixtures sets and more than four complex cardiac classes. The statistical analysis is performed on a variety of databases such as MIT/BIH Normal Sinus Rhythm (NSR), MIT/BIH Arrhythmia (AR) and MIT/BIH Atrial Fibrillation (AF) and Peripheral Pule Analyser using feature compatibility techniques. The classifiers are trained for prediction with approximately 40000 sets of parameters. The proposed model reaches an average accuracy of 97.87 percent and is sensitive and précised. The best features are chosen from the different HRV features that will be used for classification. The present model was checked under all possible subject scenarios, such as the raw database and the non-ECG signal. In this sense, robustness is defined not only by the specificity parameter, but also by other measuring output parameters. Support Vector Machine (SVM), K-nearest Neighbour (KNN), Ensemble Adaboost (EAB) with Random Forest (RF) are tested in a 5% higher precision band and a lower band configuration. The Random Forest has produced better results, and its robustness has been established.
Keywords: Heart rate variability, BioSignal, machine learning, intra group selection method, cardiac diseases, classification, robustness
DOI: 10.3233/IDT-200058
Journal: Intelligent Decision Technologies, vol. 15, no. 1, pp. 151-160, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl