Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhang, Lianga | Zhao, Zhenganga; b | Zhang, Dachenga; b; * | Luo, Chuana | Li, Chuana
Affiliations: [a] Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming, Yunnan 650500, China | [b] Yunnan Key Laboratory of Computer Technology Application, Kunming University of Science and Technology, Kunming, Yunnan 650500, China
Correspondence: [*] Corresponding author: Dacheng Zhang, Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming, Yunnan 650500, China. E-mail: dacheng.zhang@kust.edu.cn.
Abstract: The operating conditions of the transmission lines can be assessed through the information measured by the smart meters in the power supply bureau. Accurate classification of transmission line faults can be helpful to improve the maintenance strategy of smart grids. This paper analyzes the mechanism of the voltage loss and the phase fault of the transmission line by using the operation data collected by the smart meters from three power supply bureaus (named Bureau A, B and C), where the faults are labeled by expert systems. In this work, a novel Particle Swarm Optimization Pattern Recognition Neural Network (PSO-PRNN) classifier is built to accurately categorize the faults and its classification performance is compared with the ones of traditional K-Nearest Neighbor (KNN), Decision Tree (DT), PSO-KNN and PSO-DT classifiers. The results show that the classification accuracy of PSO-PRNN outperforms traditional classifiers when being applied to the data collected from all three bureaus. In the A power supply bureau are 83.0%, 88.7%, 82.0%, 86.9% and 96.1%, and the classification accuracy rates are 55.7%, 68.7%, 56.6%, 68.7% and 82.5%, when used to process the data of the bureau B. The classification accuracy is 57.1%, 66.4%, 57.2%, 69.0% and 82.1%, when processing the data of bureau C. The results show that the PSO-PRNN classifier is superior to the others in terms of accuracy and applicability.
Keywords: Transmission lines, voltage phase loss, phase break, particle swarm optimization, pattern recognition neural network
DOI: 10.3233/IDA-205695
Journal: Intelligent Data Analysis, vol. 26, no. 1, pp. 189-203, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl