Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected Proceedings of the 6th Asian Congress for Mirocirculation (ACM'05) (Tokyo, February 25 and 26, 2005)
Article type: Research Article
Authors: Seki, Junji; | Satomura, Yasuhiko; ; | Ooi, Yasuhiro | Yanagida, Toshio; | Seiyama, Akitoshi;
Affiliations: Department of Biomedical Engineering, National Cardiovascular Center Research Institute, Suita, Osaka 565-8565, Japan | Department of Physiology and Biosignaling, Osaka University Graduate School of Medicine, Suita, Osaka 565-0871, Japan | Brain Information Group, Kansai Advanced Research Center, Communications Research Laboratory, Nishi-ku, Kobe, Hyogo 651-2492, Japan | Division of Pathogenesis and Control of Oral Disease, Osaka Univ. Graduate School of Dentistry, Suita, Osaka 565-0781, Japan
Note: [] Corresponding author. E-mail: sekij@ri.ncvc.go.jp.
Abstract: In order to analyze cerebral hemodynamics and its change following neural activation, the cross-sectional profiles of blood flow velocity in the rat pial microvessels and their temporal changes were measured in vivo using Doppler OCT technique (Doppler optical coherence tomography). The OCT system used in this study has axial resolution of 11 μm and lateral resolution about 14 μm in the cortical tissue. The velocity distributions along the vertical diameter of pial microvessels in a cranial window of the rats were measured at short time intervals by scanning the OCT sampling point repeatedly. The velocity profiles obtained in the pial arterioles were parabolic at any phase, although the centerline velocity pulsated following heart beats with amplitude as large as 50% of the temporal mean velocity. It indicates that the blood flow in the pial microvessels is a quasi-steady laminar flow, which is consistent with the flow expected for the case of a small Reynolds number and a small frequency parameter. The stimulus-induced increase in velocity pulsation was much larger than the increase in the mean velocity, which places a restriction on the mechanism of regulating the regional cerebral blood flow and blood volume. The results obtained in this study showed that the Doppler OCT has a potential of measuring velocity profiles and their temporal changes with both high temporal and spatial resolutions for the pial microvessels with diameter up to 200 μm.
Keywords: Velocity profile, Doppler optical coherence tomography, pial microvessel, cardiac pulsation, electrical stimulation, functional hyperemia
Journal: Clinical Hemorheology and Microcirculation, vol. 34, no. 1-2, pp. 233-239, 2006
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl