Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Review Article
Authors: Leterrier, F.a; * | Saint-Blancard, J.b | Stoltz, J.F.c
Affiliations: [a] Division de Biophysique du Centre de Recherches du Service, de Santé des Armées, F. 92141 Clamart, France | [b] Centre de Transfusion Sanguine des Armées “Jean Julliard”, 92141 Clamart, France | [c] Groupe d’Hémorhéologie, Centre Régional de Transfusion Sanguine Brabois - F. 54500 Vandoeuvre Les Nancy, France
Correspondence: [*] To whom correspondence should be addressed.
Note: [] Accepted by: Editor-in-Chief A.L. Copley
Abstract: An enormous amount of work has been performed on the metabolic properties of the red blood cell during its storage in blood bank conditions, but the membrane structure changes (both at the molecular and at the macroscopic level) and the rheological perturbations of stored erythrocytes have been comparatively less well studied. In the last decade, the progress in our understanding of the organization and the properties of the red blood cell membrane has been considerable. It is thus interesting to review the work concerning the biophysical aspects of blood storage in the light of these recent findings. In a first part, recent advances about the normal erythrocyte are summarized, emphasizing membrane structure and rheological properties. The reviewed literature is essentially limited to 1979–1981. The second part deals with the biological and rheological pertubations caused by storage of the blood in the liquid state. Aspects of storage in the frozen state have been excluded from this review. In the third and last part the possible causes of the observed modifications are analyzed from a molecular point a view, and the advantages of recent anticoagulant and preservative solutions are indicated.
Keywords: blood conservation, erythrocyte membrane structure, erythrocyte shape, blood rheology
DOI: 10.3233/CH-1983-3107
Journal: Clinical Hemorheology and Microcirculation, vol. 3, no. 1, pp. 53-95, 1983
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl