Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected articles of the 42th Conference of the German Society for Clinical Microcirculation and Hemorheology, 15–16 November 2024, Senftenberg, Germany
Guest editors: S. Braune and F. Jung
Article type: Research Article
Authors: Kaiser, Ulricha | Kück, Fabianb | Stroszczynski, Christianc | Jung, Ernst Michaelc | Greiner, Barbarac; *
Affiliations: [a] Medical Clinic and Polyclinic III, University Hospital Regensburg, Regensburg, Germany | [b] Department of Medical Statistics, University Medical Center Göttingen, Göttingen, Germany | [c] Institute for Diagnostic Radiology and Interdisciplinary Ultrasound, University Hospital Regensburg, Regensburg, Germany
Correspondence: [*] Corresponding author: Dr. med. univ. Barbara Greiner, Department of Pediatric Radiology, Institute of Diagnostic Radiology and Interdisciplinary Ultrasound, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, Regensburg 93053 Germany. E-mail: barbara.greiner@klinik.uni-regensburg.de.
Abstract: OBJECTIVE:To assess diagnostic capabilities of a modern handheld ultrasound device (HUD) for portal vein (PV) evaluation in pediatric patients and to verify if age, body mass index (BMI) and object depth correlate to imagequality. METHODS:45 patients (3.9 months– 17.9 years; 10.3 years±5.4) were examined using a HUD and cart-based high-end ultrasound system (HEUS). The intra-and extrahepatic PV was scanned using B-Mode and Color-coded Doppler sonography (CCDS). A five-point Likert scale was applied to evaluate image quality. Results were interpreted by two readers in consensus. Scores were compared between the scanners and correlated to age, BMI and skin-to-portal-vein-distance (SPVD). The influence on image quality and the difference between the two devices were analyzed using ordinal and Bayesian logistic regression models. RESULTS:≥4 points (mild or no limitations) were achieved by the HUD in 60% for B-Mode and 56% for CCDS. There was a statistically significant negative correlation between the image quality achieved by the HUD and the SPVD for B-Mode and CCDS. The effect of BMI and SPVD on having≥4 points differed significantly between the HUD and HEUS for B-Mode and for CCDS. CONCLUSIONS:Sufficient to excellent image quality for portal vein assessment in pediatric patients was achieved by the HUD except for the most deep-lying structures. Compared to HEUS, diagnostic performance of the HUD is lower, based on a negative correlation with object depth.
Keywords: Handheld ultrasound, Vscan Air, vascular, portal vein, pediatric
DOI: 10.3233/CH-248105
Journal: Clinical Hemorheology and Microcirculation, vol. 88, no. s1, pp. S57-S68, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl