Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Kokkinidou, D.a | Kaliviotis, E.a; * | Shammas, C.b | Anayiotos, A.a | Kapnisis, K.a
Affiliations: [a] Department of Mechanical Engineering and Material Science and Engineering, Cyprus University of Technology, Limassol, Cyprus | [b] BIOANALYSIS Clinical Laboratory, Limassol, Cyprus
Correspondence: [*] Corresponding author: E. Kaliviotis, Department of Mechanical Engineering and Material Science and Engineering, Cyprus University of Technology, Limassol, Cyprus. E-mail: e.kaliviotis@cut.ac.cy.
Abstract: BACKGROUND:Even though cardiovascular stenting is widely used for the treatment of coronary artery disease, information on how it can affect the hematological and hemorheological profile is scarce in the literature. Most of the work on this issue is based on theoretical or computational fluid dynamics models, lacking in-depth in vitro and in vivo experimental verification. OBJECTIVE:This work investigates, in an in vivo setting, the effects of stenting and the implantation time-course on hematological and hemorheological parameters that could potentially compromise the device’s functionality and longevity. METHODS:Custom-made self-expanding nitinol stents were implanted in the common carotid artery of male CD1 mice. Whole blood samples were collected from control (non-stented) and stented animals at 5 and 10 weeks post-implantation. Hematological measurements and blood viscosity, red blood cell aggregation, and deformability were performed using standard techniques. RESULTS:Implant-induced changes were observed in some of the hematological and hemorheological indices. Blood viscosity seems to have been negatively affected by an increased hematocrit and reduced RBC deformability, at 10 weeks post-implantation, despite a slight decrease in RBC aggregation. CONCLUSIONS:Although the alterations observed may be the result of the peri-implant inflammatory response, the physiological consequences due to hemorheological changes need to be further investigated.
Keywords: Stents, mouse implantation model, hematology, red blood cell biomechanics, hemorheology
DOI: 10.3233/CH-231921
Journal: Clinical Hemorheology and Microcirculation, vol. 87, no. 1, pp. 39-53, 2024
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl