Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Dong, Xue-Ying | Li, Qiang-Mei | Xue, Wei-Li | Sun, Jia-Wei | Zhou, Hang | Han, Ye | Zhou, Xian-Li | Hou, Xiu-Juan; *
Affiliations: In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, Harbin, China
Correspondence: [*] Corresponding author: Xiu-Juan Hou, In-Patient Ultrasound Department, The Second Affiliated Hospital of Harbin Medical University, Surgeon’s Hall, No. 246, Xuefu Road, Nangang District, Harbin City, Heilongjiang, China. Tel.: +86 0451 86297285; E-mail: houxiujuan@126.com.
Abstract: OBJECTIVE:This study aims to analyze the performance of endorectal ultrasound (ERUS) combined with shear wave elastography (SWE) for rectal tumor staging. METHODS:Forty patients with rectal tumors who had surgery were enrolled. They underwent ERUS and SWE examinations before surgery. Pathological results were used as the gold standard for tumor staging. The stiffness values of the rectal tumor, peritumoral fat, distal normal intestinal wall, and distal perirectal fat were analyzed. The diagnostic accuracy of ERUS stage, tumor SWE stage, ERUS combined with tumor SWE stage, and ERUS combined with peritumoral fat SWE stage were compared and evaluated by receiver operating characteristic (ROC) curve to select the best staging index. RESULTS:From T1 to T3 stage, the maximum elasticity (Emax) of the rectal tumor increased gradually (p < 0.05). The cut-off values of adenoma/T1 and T2, T2 and T3 tumors were 36.75 and 85.15kPa, respectively. The diagnostic coincidence rate of tumor SWE stage was higher than that of ERUS stage. Overall diagnostic accuracy of ERUS combined with peritumoral fat SWE Emax restaging was significantly higher than that of ERUS. CONCLUSIONS:ERUS combined with peritumoral fat SWE Emax for tumor restaging can effectively distinguish between stage T2 and T3 rectal tumors, which provides an effective imaging basis for clinical decisions.
Keywords: Endorectal ultrasound, shear wave elastography, rectal tumor, peritumoral fat, diagnostic performance
DOI: 10.3233/CH-231716
Journal: Clinical Hemorheology and Microcirculation, vol. 84, no. 4, pp. 399-411, 2023
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl