Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Lu, Dian Yuana | Liu, Lana | Shen, Lia | Cai, Jian Ronga | Xu, Lia | Xiang, Li Huab; *
Affiliations: [a] Department of Ultrasound in Medicine, Chongming Branch of Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China | [b] Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Tongji University School of Medicine, Shanghai, China
Correspondence: [*] Corresponding author: Li Hua Xiang, Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, Tongji University School of Medicine, 301 Yanchang Middle Road, Shanghai 200072, China. E-mail: xianglihua1121@163.com.
Abstract: OBJECTIVE:To investigate prostate cancer detection rate of different biopsy protocols in different PSA value groups in rural China. METHODS:A total of 186 patients underwent contrast-enhanced ultrasound (CEUS) in order to determine the puncture target prior to biopsy were enrolled in this retrospective study. All patients underwent 12-core SB combined with CEUS-TB. The biopsy results of different biopsy protocols were compared in patients with stratification by PSA value. RESULTS:Among the 186 patients underwent prostate biopsy, the histopathologic results revealed prostate cancer (PCa) in 117 cases (62.9%) and benign lesions in 69 cases (37.1%). The PCa detection rate between 8-core SB and 12-core SB showed no significant difference in PSA 4–10 ng/ml group, while the 12-core SB was significantly higher than CEUS-TB (44.9% versus 32.7%, P = 0.01). In PSA 10–20 ng/ml group, the significant difference was not seen between SB and CEUS-TB (50.0% versus 45.7%, P = 0.15). As for PSA greater than 20 ng/ml group, the PCa detection rate by SB was higher than CEUS-TB, but showed no statistically significance (79.1% versus 76.9%, P = 0.15). In the overall patients, the biopsy core positive rate of CEUS-TB was significantly higher than SB (97% versus 55.5% and 28.5%, P = 0.0001). CONCLUSION:The flexible use of SB combined with CEUS-TB can reduce the number of biopsy cores in higher PSA groups. It has clinical importance in the detection of PCa in different PSA value groups in rural China.
Keywords: PSA value, contrast-enhanced ultrasound, systematic biopsy, CEUS-targeted biopsy, prostate cancer
DOI: 10.3233/CH-200993
Journal: Clinical Hemorheology and Microcirculation, vol. 77, no. 3, pp. 295-301, 2021
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl