Article type: Research Article
Authors: Chung, Young Haka | Lee, Kyung Ahb | Cho, Minheea | Shin, Sehyunc | Lee, Byoung Kwona; *
Affiliations: [a] Department of Internal Medicine, Division of Cardiology, College of Medicine, Yonsei University, Seoul, Korea | [b] Department of Laboratory Medicine, College of Medicine, Yonsei University, Seoul, Korea | [c] Department of Mechanical Engineering, Korea University, Seoul, Korea
Correspondence: [*] Corresponding author: Byoung Kwon Lee, MD, Department of Internal Medicine, Division of Cardiology, Gangnam Severance Hospital, Yonsei University College of Medicine, 211 Eonju-ro, Gangnam-gu, Seoul 06273, South Korea. Tel.: +82 2 2019 3307; Fax: +82 2 3463 3882; E-mail: cardiobk@yuhs.ac.
Abstract: BACKGROUND:Analysis of responsiveness to antiplatelet therapy is crucial in the management of patients with cardiovascular diseases. OBJECTIVE:This study aimed to evaluate a new platelet function analysis system (Anysis-200) and to compare it with VerifyNow (Accumetrics, San Diego, CA, USA) in cardiology patients. METHODS:Overall, 125 citrated blood samples were collected from 85 cardiology patients referred for platelet function testing. In Anysis-200, platelet function was measured as blood migration distance (MD) until clogging of flow passage, which is comparable to aspirin resistance units obtained using VerifyNow. The two devices were simultaneously used and compared. RESULTS:The MDs before and after taking aspirin were 175±51 and 247±27 mm, respectively (p < 0.0001). Compared with VerifyNow (reference), the sensitivity and specificity of Anysis-200 was 91.5% and 75.5%, respectively (area under the curve, 0.829). Further, the true positive rate in patients newly taking aspirin was 85% for VerifyNow and 92.5% for Anysis-200, respectively. The Cohen’s kappa coefficient between the two devices was 0.682, indicating a relatively high agreement. CONCLUSIONS:Anysis-200, a novel system for assessing platelet aggregation, has accuracy and precision equivalent to that of, and significant agreement with, VerifyNow. Anysis-200 may be useful in screening patients with abnormal platelet reactivity and aspirin nonresponsiveness.
Keywords: Platelet function, aspirin, Anysis-200 analyzer, VerifyNow
DOI: 10.3233/CH-200822
Journal: Clinical Hemorheology and Microcirculation, vol. 76, no. 1, pp. 33-42, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl