Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Dong, Yia | Wang, Wen-Pinga; * | Lin, Panb | Fan, Peilia | Mao, Fenga
Affiliations: [a] Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China | [b] Department of Nephrology, Zhongshan Hospital, Fudan University, Shanghai, China
Correspondence: [*] Corresponding author: Wen-Ping Wang, Department of Ultrasound, Zhongshan Hospital, Fudan University, 180 Fenglin Rd, Shanghai 200032, China. Tel.: +86 13 681975670; Fax: +86 21 64220319; E-mail: puguang61@126.com.
Abstract: OBJECTIVE:We performed a prospective study to evaluate the value of contrast-enhanced ultrasound (CEUS) in quantitative evaluation of renal cortex perfusion in patients suspected of early diabetic nephropathies (DN), with the estimated GFR (MDRD equation) as the gold standard. METHODS:The study protocol was approved by the hospital review board; each patient gave written informed consent. Our study included 46 cases (21 males and 25 females, mean age 55.6 ± 4.14 years) of clinical confirmed early DN patients. After intravenous bolus injection of 1 ml sulfur hexafluoride microbubbles of ultrasound contrast agent, real time CEUS of renal cortex was performed successively using a 2–5 MHz convex probe. Time-intensity curves (TICs) and quantitative indexes were created with Qlab software. Receiver operating characteristic (ROC) curves were used to predict the diagnostic criteria of CEUS quantitative indexes, and their diagnostic efficiencies were compared with resistance index (RI) and peak systolic velocity (PSV) of renal segmental arteries by chi square test. Our control group included forty-five healthy volunteers. Difference was considered statistically significant with P < 0.05. RESULTS:Changes of area under curve (AUC), derived peak intensity (DPI) were statistically significant (P < 0.05). DPI less than 12 and AUC greater than 1400 had high utility in DN, with 71.7% and 67.3% sensitivity, 77.8% and 80.0% specificity. These results were significantly better than those obtained with RI and PSV which had no significant difference in early stage of DN (P > 0.05). CONCLUSIONS:CEUS might be helpful to improve early diagnosis of DN by quantitative analyses. AUC and DPI might be valuable quantitative indexes.
Keywords: Contrast-enhanced ultrasound, color doppler flow imaging, diabetic nephropathies, time-intensity curve, quantitative index
DOI: 10.3233/CH-151967
Journal: Clinical Hemorheology and Microcirculation, vol. 62, no. 3, pp. 229-238, 2016
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl