Article type: Research Article
Authors: Park, Seong Juna | Yoon, Junga; * | Seo, Hong Seogb; * | Lim, Chae Seunga
Affiliations: [a] Department of Laboratory Medicine, College of Medicine, Korea University Seoul, South Korea | [b] Division of Cardiology, Internal Medicine, College of Medicine, Korea University Seoul, South Korea
Correspondence: [*] Corresponding authors: Hong Seog Seo, MD, Division of Cardiology, Department of Medicine, Guro Hospital, Korea University College of Medicine, Guro 2 Dong, Guro Gu, Seoul 152-703, Korea. Tel.: +82 2 2626 3018; Fax: +82 2 2626 1069; E-mail: mdhsseo@korea.ac.kr. and Jung Yoon, MD, Department of Laboratory Medicine, Guro Hospital, Korea University College of Medicine, 148 Guro Dong Ro, Guro Gu, Seoul 08308, Korea. Tel.: +82 2 2626 3242; Fax: +82 2 2626 1465; E-mail: unoaotro@korea.ac.kr.
Abstract: BACKGROUND:Platelet function analysis is crucial in assessing the hemostatic status to evaluate congenital and acquired platelet function defects. The Anysis-200 analyzer is a new automated lab-on-a-chip-based platelet function analyzer. OBJECTIVE:We aimed to evaluate a new platelet function analyzing system, the Anysis-200 in comparison to the Platelet Function Analyzer (PFA)-200 in cardiac patients. METHODS:Citrated blood was collected from 174 patients who visited the Department of Cardiology. The Anysis-200 consists of two kits, the microchips with collagen and epinephrine-coated membrane (C/EPI) or adenosine diphosphate-coated membrane (C/ADP). Platelet clogging in the Anysis-200 is measured by the blood migration distance obtained by a camera, which is compatible with the closure time in the PFA-200. We performed Anysis-200 and PFA-200 analyzers simultaneously and compared the results. RESULTS:The sensitivity and specificity of the Anysis-200 C/EPI kit in comparison to the PFA-200 C/EPI kit were 63.41% and 91.43%, respectively. Regarding the C/ADP kit, the sensitivity and specificity of the Anysis-200 were 58.97% and 74.29%, respectively. The agreement rate between the Anysis-200 and PFA-200 for C/EPI was 83.35% and 70.14% for C/ADP. CONCLUSIONS:The Anysis-200, which applies a novel method to detect platelet clogging, has shown moderate to fair agreement with the PFA-200. This test is potentially useful for screening cardiac patients with an abnormal platelet function.
Keywords: Platelet function, Anysis-200 analyzer, PFA-200 analyzer
DOI: 10.3233/CH-190801
Journal: Clinical Hemorheology and Microcirculation, vol. 80, no. 1, pp. 17-24, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl