Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Lerchbaumer, Markus Herberta; * | Kleemann, Tobiasb | Jung, Ernst-Michaelc | Nagel, Sebastiana | Hamm, Bernda | Fischer, Thomasa
Affiliations: [a] Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Radiology, Berlin, Germany | [b] Carl-Thiem-Klinikum, Department of Gastroenterology, Cottbus, Germany | [c] Department of Radiology, University Medical Center Regensburg, Regensburg, Germany
Correspondence: [*] Corresponding author: Markus H. Lerchbaumer, MD, Department of Radiology, Interdisciplinary Ultrasound Center Charité – Universitätsmedizin Berlin Campus Charité Mitte, Charitéplatz 1, 10117 Berlin, Germany. Tel.: +49(0)30 450 657084; Fax: +49(0)30 450 7557901; E-mail: markus.lerchbaumer@charite.de.
Abstract: BACKGROUND:Contrast-enhanced ultrasound (CEUS) has been used as an additional imaging technique in order to clarify rare focal splenic lesions (FSL). CEUS is a safe and cost-effective modality for assessment of perfusion. OBJECTIVE:To validate contrast enhancement pattern and evaluate the diagnostic accuracy of CEUS in unclear FSL. METHODS:CEUS examinations of the spleen in 50 patients between 2012 and 2018 were included in the study. Examinations were performed using B-mode, colour-coded Doppler ultrasound (CCDS) and CEUS after injection of sulphur hexafluoride microbubbles and interpreted in consensus by two experienced radiologists. Reference standard was defined as histopathological report and clinical course (treatment response, long term follow up). RESULTS:All patients were successfully examined by CEUS without an adverse reaction. CEUS presented the correct differentiation of benign and malignant alterations in 49/50 (98%). Lesion washout was found in all malignant but also 16.7% of all benign lesions. Matched to the histopathological report and clinical follow up, CEUS represented a sensitivity of 100% (95% -CI, 57–100), a specificity of 98% (95% -CI, 88–100), a positive predictive value (PPV) of 83% (95% -CI, 44–97) and a negative predictive value (NPV) of 100% (95% -CI, 92–100). CONCLUSION:CEUS may provide additional information by visualization of dynamic contrast enhancement pattern to differentiate benign and malignant lesions. Nevertheless, established criteria for malignancy (early enhancement or washout) in FSL should be considered with caution since they are also found in benign lesions.
Keywords: Contrast-enhanced ultrasound, CEUS, focal splenic lesions
DOI: 10.3233/CH-190758
Journal: Clinical Hemorheology and Microcirculation, vol. 75, no. 2, pp. 177-188, 2020
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl