Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Issue title: Selected Papers of the Joint Conference of the ESCHM-ISCH-ISB-2018, 2-6 July, 2018, Krakow, Poland
Guest editors: F. Jung and M. Fornal
Article type: Research Article
Authors: Mrowietz, C.a | Franke, R.P.b | Pindur, G.a | Sternitzky, R.c | Jung, F.d | Wolf, U.e; *
Affiliations: [a] Institute for Clinical Hemostasiology and Transfusion Medicine, University Saarland, Homburg/Saar, Germany | [b] Central Institute for Biomedical Engineering, University of Ulm, Germany | [c] Praxisklinik Herz und Gefäße, Dresden, Germany | [d] Institute of Biomaterial Science and Berlin-Brandenburg Center for Regenerative Therapies, Helmholtz-Zentrum Geesthacht, Teltow, Germany | [e] University of Applied Sciences Fulda, Germany
Correspondence: [*] Corresponding author: U. Wolf, University of Applied Sciences Fulda, Germany. E-mail: udo.wolf@pg.hs-fulda.de.
Abstract: BACKGROUND:The laser Doppler fluxmetry (LDF) is a non-invasive method to assess skin blood perfusion, measuring the flow of blood cells inside a tissue volume without harming the tissue. In the diagnosis of skin circulation disorders, the results of the LDF measurement are generally used in such a way that “normal” (or non-ill) or “pathological” values are achieved by comparison with a reference sample, for example of apparently healthy subjects. MATERIAL AND METHODS: In this study, the values of LDF for the diagnosis of microcirculatory disorders in patients with coronary artery disease (n = 20) or in patients with microcirculatory disorders, already diagnosed by capillary microscopy (n = 46), were examined. RESULTS:The mean values of LD amplitudes in the four frequency windows for patients with coronary artery disease were in the reference range. However, some of the patients showed reduced LD values: in eleven of the twenty patients, one or more mean LD amplitudes were below the reference range. Four of the eleven patients had pathologically decreased capillary erythrocyte velocities of very = 0.09–0.21 [mm/s], while the other seven patients had normal blood circulation at rest.For all patients with a proven cutaneous microcirculatory disorder, the mean LD amplitude in at least one of the frequency windows FF2 to FF4 was pathologically reduced. CONCLUSION:The Laser-Doppler fluxmetry method used in the study allows the reliable diagnosis of cutaneous microcirculatory disorders.
Keywords: Laser-Doppler fluxmetry, cutaneous microcirculation, atherosclerosis
DOI: 10.3233/CH-189402
Journal: Clinical Hemorheology and Microcirculation, vol. 71, no. 2, pp. 129-135, 2019
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
sales@iospress.com
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
info@iospress.nl
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office info@iospress.nl
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
china@iospress.cn
For editorial issues, like the status of your submitted paper or proposals, write to editorial@iospress.nl
如果您在出版方面需要帮助或有任何建, 件至: editorial@iospress.nl